LG AS-W096QGG1 Service Manual page 75

Table of Contents

Advertisement

The Outdoor Unit does not operate at all.
Trouble 7
Does the Operating LED of indoor unit blink
when Operation's ON?
Is the Connection between indoor power
relay Pin
and terminal block No. 1 right?
Is the connection of cable between indoor
and outdoor unit right?
Is the voltage of Terminal Block
outdoor Control Box about AC220V /
240V?
Is the voltage of NF01J
PCB Ass'y about AC220V / 240V when
Operation's ON?
Is the Bridge Diode(BD01S) right?
Replace the PCB Ass'y.
NO
YES
YES
,
in
YES
,
in outdoor
YES
NO
YES
Refer to the self-diagnosis function.
NO
Check the connecting state of connector
NO
Indoor
1(Brown)
2(Blue)
3(Green/YL)
4(Red)
NO
Check the Fuse of Outdoor PCB Ass'y.
NO
Check the PTC and RY-PWR.
NO
Check the Bring Diode.
Troubleshooting Guide
Outdoor
1(Brown)
2(Blue)
3(Green/YL)
4(Red)
Service Manual 75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-w126rgh1As-w246tlg1As-w186tgh1As-w246tgh1