Installation Site Choosing; Indoor Unit Installation; Indoor Unit Mounting Plate; Installation Process - Carrier 38QHM009 Installation Manual

Wall mounted air conditioner
Table of Contents

Advertisement

1. PREPARING FOR INSTALLATION
 

1.3 INSTALLATION SITE CHOOSING

Indoor Unit
- A location which can bear the weight of indoor unit.
- Do not install indoor units near a direct source of heat such as direct sunlight or a heating appliance.
- A location which provides appropriate clearances as below figure.
- Moving parts of appliance must be installed/located at the level not less than 2.3m from the floor.
Outdoor Unit
- A location which is convenient to installation and not exposed to strong wind. If unit is exposed to strong winds it is recommended
that a wind baffle be used.
- A location which can bear the weight of outdoor unit and where the outdoor unit can be mounted in a level position.
- A location which provides appropriate clearances as below figure.
Do not install the indoor or outdoor units in a location with special environmental conditions.
Confirm that there is enough room for installation and maintenance.
Note: Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
The refrigerant lines may be routed
Put a cushioning material to have
in any of the four directions.
installation space for rear tubing.
Left
Right-rear
tubing
tubing
Left-rear tubing
Right tubing
05
If drain cap exist, the drain hose
can be exchanged.
Drain cap
Cushioning
material

2. INDOOR UNIT INSTALLATION

 
2.1 INDOOR UNIT MOUNTIN PLATE
The mounting plate will look like one of the following depending on the unit size.
The holes for fixing anchors should be 5mm. (unit:mm)
Indoor unit outline
23.2/0.9
Left rear side
45/1.8
refrigerant
260/10.2
135/5.3
pipe hole
990/39
φ65/2.6
42QHM009ES*/42QHM012ES*
Indoor unit outline
275/10.8
257/10.1
Left rear side
refrigerant
pipe hole
1186/46.7
φ65/2.6
42QHM018ES*/42QHM024ES*
Install The Mounting Plate
Fix the mounting plate horizontally and level on the wall with five or more A-type
screws.
Drill Hole In The Wall
Drill a 65mm hole on the wall which is slightly tilted towards the outside.
Wall
Outdoor
Indoor

2.2 INSTALLATION PROCESS

Step 1: Determine Wall Hole Position
Right rear side
refrigerant
pipe hole
φ65/2.6
Step 2: Attach Mounting Plate
Right rear side
refrigerant
pipe hole
φ65/2.6
Step 3: Drill Wall Hole
Step 4: Connect Pipe
Step 5: Connect Wire
L
N
S
06