12-3 REFRIGERATION CYCLE
Troubleshooting Chart
CAUSE
PARTIAL
LEAKAGE
COMPLETE
LEAKAGE
PARTIAL
CLOG
WHOLE
CLOG
MOISTURE CLOG
COMP-
RESSION
NO COMP-
RESSION

12-3-1 Cleaning

There is no need for routine condenser cleaning in normal Home operating environments. If the environment is
particularly greasy or dusty, or there is significant pet traffic in the home, the condenser should be cleaned
every 2 to 3 months to ensure maximum efficiency.

If you need to clean the condenser:

Remove the mechanical cover.
Use a vacuum cleaner with a soft brush to clean the grille, the open areas behind the grille and the front
surface area of the condenser.
Replace the mechanical cover.
STATE OF
THE UNIT
Freezer
Low flowing sound of
compartment and
Refrigerant is heard
Refrigerator don't
and frost forms in
cool normally.
inlet only.
Freezer
Flowing sound of
compartment and
refrigerant is not
Refrigerator don't
heard and frost isn't
cool normally.
formed.
Freezer
Flowing sound of
compartment and
refrigerant is heard
Refrigerator don't
and frost forms in
cool normally.
inlet only.
Freezer
Flowing sound of
compartment and
refrigerant is not
Refrigerator don't
heard and frost isn't
cool.
formed.
Cooling operation
Flowing sound of
stops periodically.
refrigerant is not
heard and frost melts.
Freezer and
Low flowing sound of
Refrigerator don't
refrigerant is heard
cool.
and frost forms in
inlet only.
No compressing
Flowing sound of
operation.
refrigerant is not
heard and there is
no frost.
TEMPERATURE
STATE OF THE
EVAPORATOR
COMPRESSOR
A little higher than
ambient
temperature.
Equal to ambient
temperature.
A little higher than
ambient
temperature.
Equal to ambient
temperature.
Lower than ambient
temperature.
A little higher than
ambient
temperature.
Equal to ambient
temperature.
OF THE
• Refrigerant level is low due
to a leak.
• Normal cooling is possible by
restoring the normal amount
of refrigerant and repairing
the leak.
• No discharging of
Refrigerant.
• Normal cooling is possible by
restoring the normal amount
of refrigerant and repairing
the leak.
• Normal discharging of the
refrigerant.
• The capillary tube is faulty.
• Normal discharging of the
Refrigerant.
• Cooling operation restarts
when heating the inlet of the
capillary tube.
• Low pressure at high side of
compressor due to low
refrigerant level.
• No pressure in the high
pressure part of the
compressor.
REMARKS