Kenwood TK-785 Service Manual page 49

Hide thumbs Also See for TK-785:
Table of Contents

Advertisement

Item
Condition
3. High power
1) Set test mode
Select "HPOW" in tuning mode. F. counter panel
"L HPOW"
PTT : ON
2) "L2 HPOW"
PTT : ON
3) "C HPOW"
PTT : ON
4) "H2 HPOW"
PTT : ON
5) "H HPOW"
PTT : ON
4. Low power
1) Set test mode
Select "LPOW" in tuning mode.
"L LPOW"
PTT : ON
2) "L2 LPOW"
PTT : ON
3) "C LPOW"
PTT : ON
4) "H2 LPOW"
PTT : ON
5) "H LPOW"
PTT : ON
5. Power check 1) Set test mode
CH : CH1 - Sig1
CH2 - Sig1
CH3 - Sig1
PTT : ON
6. Modulation
1) Set test mode
balance
MIC input : OFF
Select "BAL" in tuning mode. meter
"L BAL"
Deviation meter filter
LPF : 3kHz
HPF : OFF
De-emphasis : OFF
2) "C BAL"
PTT : ON
3) "H BAL"
PTT : ON
7. Maximum
1) Set test mode
deviation
Connect AG to the MIC
terminal.
Select "MAX" in tuning mode.
"L MAX"
AG : 1kHz/40mV
Deviation meter filter
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
2) "C MAX"
PTT : ON
3) "H MAX"
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Power meter
Power meter
ANT
Ammeter
DC IN
Power meter Rear
ANT
Deviation
panel
Oscilloscope
AF VTVM Front
MIC
AG
panel
Adjustment
Parts
Method
± 1.0W
10.0W K
15.0W E
25.0W M
± 0.5W
5.0W
Check
10W±1W, 6A or less K
15W±1W, 6A or less E
25W±1W, 8A or less M
Make the de-
modulation
waveform near.
2.05kHz
+0Hz/–50Hz
(According to the
larger +, –)
TK-785
Specifications/Remarks