Carrier Circuits 50A 240V Installation Manual page 7

Automatic home standby generators
Table of Contents

Advertisement

10a
10b
1-3/4" Diameter Hole
1-3/4" Diameter Hole
11a
The outer diameter of the conduit connector is 1-1/16"
11b
The outer diameter of the threaded end is 15/16".
Although you may choose to perform
electrical connections yourself,
DANGER
CARRIER
recommends
licensed electrician or individual with complete
knowledge of electricity perform the procedures
in sections 12, 13a, and 13b.
Switch service main circuit breaker
to off" or open position prior to
DANGER
removal of cover or removal of any
wiring of the main electrical distribution panel.
The wires connected to
the service main circuit
breaker remain live or
"hot". Avoid contact with
these wires and the
service main circuit breaker connection lugs.
NOTE: Balance must be maintained when moving
circuit
locations
from
distribution panel to emergency load center.
Circuit breaker positions alternate buss bars
vertically. Circuits sharing a neutral wire should
either be moved together to adjacent positions in
emergency load center or not moved. If you are
unsure of proper procedure or if your installation
differs from that described in this guide, consult
a licensed professional at this time.
STEP 3
10a. Determine where the flexible conduit will pass through the house from inside to outside.
When you are certain you have clearance on each side and within the wall, drill a small pilot
hole through the wall to mark the location.
10b. Using a hole saw, drill a 1-3/4 inch diameter hole in the house's wall to allow the conduit
to fit through.
11a. From the inside of the house, feed the end of the 30-foot conduit (which is pre-wired from
transfer switch) through the wall to outside.
11b. Remove the threaded lock nut from the conduit coupling.
11c. Lift cover. Remove internal cover plate screw and internal cover.
Silicone Caulk
Remove the knock out in the lower right corner of the external
connection box. From the rear of the connection box, feed wires
& 4 pin plug into box. Slip the lock nut over wires and plug and
tighten securely onto conduit coupling. Using appropriate
fasteners, mount external connection box over pre-drilled hole to
fully conceal the hole. Seal around the hole and conduit with
silicone caulk from both the inside and outside of the home.
Also, caulk around the sides and top of the box to seal the edges to the siding or wall.
Connect wires to lugs; Black to black, white to white, and red to red. Torque nuts to 20
in/lbs. Snap together the 4-pin plug connector. Loosen nut from grounding lug and attach
ground wire (green) from conduit. Reinstall nut and tighten to 45 in/lbs. Reinstall internal
cover plate and screw. Close cover and install lock. This wiring is complete.
that
a
STEP 4
12. Locate automatic transfer switch with built-in emergency load center within one foot of
main distribution panel. The automatic
transfer switch with built-in load center can
be located to the left or right of main
distribution panel. Hold transfer switch
against the mounting surface. Level the
transfer switch and mark the mounting
holes. Drill the appropriate size pilot holes.
Mount automatic transfer switch with built-
in load center to mounting surface with
appropriate fasteners.
STEP 5
main
electrical
13a. Remove the main electrical distribution panel cover. Remove
appropriate size knockout from the bottom or side of the main panel.
(A 2-foot flexible conduit is pre-wired from the transfer switch with
built-in load center.) Remove threaded lock nut from conduit
coupling. Feed all wires through knockout into main panel. Slip lock
nut over wires and tighten securely on conduit coupling. Remove the
black (hot) wire from a circuit breaker that protects a circuit you
want to have powered in the event of a power failure. - continued on
page 8
CONNECTION TO EXTERNAL CONNECTION BOX
The external connection box must be locked to
ensure safety and to discourage tampering.
WARNING
MOUNTING THE AUTOMATIC TRANSFER SWITCH
CONNECTION OF EMERGENCY CIRCUITS
11c
Ground
Screw
12
1 ft.
13a
Knockout
7