The only periodic maintenance required is change the oil every 2000 hours and
change the filter whenever it becomes clogged. The filter unit consists of a
screw-off canister and replaceable filter element.
5.2.
Field Test Reservoir Draining/ Refilling Procedure
This is a closed-loop system. If general cleanliness methods are followed,
the filter should not require replacement for long periods of time. Oil should be
changed every 2000 hours of pump operation.
5.3.
Change Oil Filter
Unscrew the bottom of the container and change the cartridge.
See Drawing B-30221 - Item #13 for filter model number
6.

Troubleshooting

This section lists the most common problems encountered, as well as their probable
causes. If the problem cannot be readily corrected, contact your Xcite Customer Ser-
vice Representative.
Power lamp is not lit when unit is plugged in.
Fuses blown.
Unit shuts off 2-4 seconds after power is applied.
Low hydraulic pressure (less than 3000 psi.)
Always clean the quick-disconnects before making any
connections.
Make sure the heat exchanger fan is not blocked during
operation.
If the supply is to be transported such that the cabinet could be
tipped over, the oil should be drained from the reservoir. See
draining and filling procedure in Section 2.1.
Problem
Field Test Power Supply
FTPS - 6
Probable Cause
Check power source.
Low line voltage or motor
malfunction.
Dirty filter element.
Excessive flow beyond
1.2GPM.
Defective relief valve