Physical
Height
Width
Depth
Weight
Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
10
Getting Started With Your System
42.03 cm (16.55 in)
18.90 cm (7.44 in)
46.38 cm (18.25 in)
16.1 kg (35.49 lb)
10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
–40 °C to 65 °C (–40 °F to 149 °F) with
a maximum temperature gradation
of 20 °C per hour
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.26 Grms at 5 Hz–350 Hz for 15 min
1.87 Grms at 10 Hz–500 Hz for 15 min