4.1.2.3
Mounting clearances
► Ensure the distances indicated on the diagram.
This will ensure that the connections to the water can be
accessed and inspected.
Additional clearances around the appliance may be
advantageous for its installation and maintenance.
20
20
min.
min.
i
Notes
* Clearance necessary for the installation or
maintenance of the appliance.
4.1.3
Considering the product location
4.1.3.1
Surrounding conditions
► Ensure that the room in which the appliance is installed
is not heated to the maximum recommended room
temperature. Recommended room temperature: 25°C.
► Do not install the product above another product that
could damage it (for example, above a cooker that might
emit steam or grease) or in a room, which has a lot of
dust in the atmosphere which is corrosive.
► Do not install the product under another product that
might leak.
► Make sure that the room where you want to fi t the
product is suffi ciently protected against frost.
4.1.3.2
Properties of the mounting surface
► Before choosing a site for the product, carefully read
the safety warnings and instructions in the operating
instructions and installation instructions.
► Ensure that the wall to which the product will be mounted
on is structurally safe in order to support the weight of the
product.
0020166669_04 - 03/15 - Vaillant
MOUNTING AND INSTALLATION
4.2

Mounting the product

4.2.1
Removing the casing
1
>600*
Key
► Remove the front casing (1).
4.2.2
Wall-mounting of the product
Danger!
a
Danger to life if the load-bearing
capacity of the fixing elements
used is insufficient!
If the fixing elements do not have
sufficient load-bearing capacity, the
product can come loose and fall
down.
► Determine the assembly location.
► Drill the holes to receive the fastenings.
► Fix the hanging bracket on the wall.
Key
1
Front casing
When fitting the product, ensure
that the fixing elements have a
sufficient loadbearing capacity.
1
Hanging bracket
1
19