Safety Precautions Do not operate or work on this equipment unless you have read and understand the instructions and warnings in this manual. Contact any Rice Lake Weighing Systems dealer for replacement manuals. Proper care is your responsibility. General Safety WARNING Failure to heed may result in serious injury or death.
• Never remove the iDimension 100’s head cover or the electrical connection panels at the base of the pole assembly. • Never modify or attempt to repair the unit. Service must be performed only by Rice Lake Weighing Systems. • Handle cables and cable connectors with care. Never use damaged power cords or plugs or loose electrical sockets.
Assembly Pole Assembly Screws to be left Screws to be removed in place Alignment Point Figure 2-1. Remove Screws 1. Using the appropriate hex wrench, remove the two screws at the pole joint. Retain the screws for assembly. Leave the other two screws in place. 2.
Cable Shroud Display Cable Power Block Base Figure 2-4. Pole Assembly 10. Stand the assembled pole upright. Head Attachment Screws Slide direction Figure 2-5. Remove Cable Shroud Cover 1. Loosen the four screws that secure the cable shroud cover. Do not remove them. 2.
Page 9
The cables and ports on back of the head are labeled for easy connections. Figure 2-7. Cable Connections Cable Order Cable Label Port Label Ethernet Ethernet USB 3 USB 3 USB 2 USB 2 Auxiliary power only Power only 1 24 VDC in Input: 24v Table 2-1.
Shroud Cover Figure 2-9. Reinstall Shroud Cover 7. Place the shroud cover in the cable shroud and slide it forward until it clicks into place. 8. Re-tighten the fours screws that secure it. Figure 2-10. Tighten Head Screws 9. Tighten the bolts that attach the head to the shroud. Display Assembly U-Shaped Bracket...
Page 11
Figure 2-12. Cable Cover 2. Remove the cable cover on the back of the display (for attachment of the USB cable in steps 5 and 6). Figure 2-13. Select Display Location 3. Select the display location. The display is usually mounted just above the display cable opening. It’s possible to mount the display up to six inches above or below the opening.
Figure 2-15. Insert Display Cable 5. Insert the display cable into the mini USB port. 6. Route the USB cable into the cable slot and replace the cover that was removed in step 2 above. 7. Remove the overlay that protects the display screen. The USB port is for attaching a scale that is compatible with the iDimension 100.
Setup The iDimension 100 is now ready to be plugged in. When it is, the software setup process will begin automatically. Don’t plug in the unit until there is time to complete all of the setup steps. Additional setup may be required for connecting a compatible scale, placing the unit in its permanent location or interfacing to a compatible software program.
Page 14
Figure 3-3. Time Zone Setup 5. Using the arrows, select the time zone for the iDimension 100. Up/Down 6. Press the to continue. Check Mark Figure 3-4. Time and Date Setup 7. Using the arrows, adjust the date and time if necessary. Up/Down 8.
Page 15
Figure 3-5. Base Selection Zero Height calibration allows iDimension 100 to calculate the distance between the scan head and the base. The process differs depending on whether the base is flat or uneven. 9. Select the scale base that is being used. •...
Page 16
Figure 3-7. Clear Scale It is important to keep the base clear and unobstructed during zero height calibration, so that it can set Zero Height accurately. 12. Clear the base. Figure 3-8. Stand Clear of Device 13. Stand clear of device while the countdown completes. iDimension 100 Assembly Instructions...
Page 17
Figure 3-9. Zero Height Complete 14. If a calibration object was used, remove it from the base. 15. Press the to continue. Check Mark Figure 3-10. Identify Scan Area The Scan Zone (Work Zone) is the area in which the unit looks for motion during the dimensioning of items. For best performance, adjust this to cover the largest area possible that can be used for scanning items and can be kept clear of all other objects.
Page 18
Figure 3-11. Setup Complete 18. Press the to begin using the iDimension 100. Check Mark Figure 3-12. Confirm calibration 19. Test the iDimension 100 to ensure it is properly calibrated. Place the calibration object on the base or scale and check the displayed dimensions. 20.
Advanced configuration with QubeVu Manager The QubeVu Manager is an optional set of software tools provided to enable advanced configuration. They are not needed in most cases. They are recommended for use only by a technical systems administrator. This introduction is not intended as a replacement for complete documentation. Please refer to the QubeVu Manager Guide for a complete guide to the tools.
Page 22
Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.in m.ricelake.com...