Agilent Technologies 6621A Operating Manual page 19

Multiple output linear system dc power supplies
Hide thumbs Also See for 6621A:
Table of Contents

Advertisement

Outputs
Programming Resolution:
Voltage
+Current
OVP
Readback Resolution:
Voltage
+ or-Current
Fixed Overvoltage Protection: (Measure at output terminals +V and -V):
Minimum
Nominal
Maximum
AC Input Power and Current:
Maximum Power = 550 W
High Line Inrush Current
(pk)
High Line Input Current
(rms)
Fuse Rating
GP-IB Interface Capabilities:
SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT0, C0, E1
Current Sink Capability:
Current sink limits are fixed approximately 10% higher than the maximum current source limits for a given operating
voltage at any voltage above 2.5 V (see Chapter 4).
Command Processing Time: (see Figure 1-3):
7 milliseconds typical (with front panel display disabled). Using STO and RCL commands allows you to change all the
voltage and current settings in about 10 mS (with front panel display disabled).
Series and Parallel Operation:
Two outputs can be operated directly in parallel or can be connected for straight series operation. Refer to Chapter 4 for
more information.
Reactive Load Capability:
All outputs have been designed with the ability to operate with significant reactive loads without instability (refer to
Figures 1-4 through 1-6).
Table 1-3. Supplemental Characteristics (continued)
40 W Low
40 W High
Voltage
Voltage
6 mV
15 mV
25 mA
10 mA
100 mV
250 mV
6 mV
15 mV
2 mA
0.8 mA
22.5 V
56 V
24 V
60 V
26 V
64 V
100 V Option
120 V Option
85 A
85 A
6.3 A
5.7 A
8 A
8 A
80 W Low
80 W High
Voltage
Voltage
6 mV
15 mV
50 mA
20 mA
100 mV
250 mV
6 mV
15 mV
4 mA
1.6 mA
22.5 V
56 V
24 V
60 V
26 V
64 V
220 V Option
240 V Option
50 A
50 A
3.0 A
3.0 A
4 A
4 A
General Information 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6627a6625a6626a6622a6628a6629a ... Show all

Table of Contents