Summary of Contents for iNels RF

  • Page 1: Installation Manual

    Installation manual iNELS RF Control www.elkoep.com...
  • Page 2: Table Of Contents

    Czech Repub- and more are constantly being added as demand How the iNELS RF Control can control an extensive installation lic. We are proud to have been your partners in is constantly increasing for our products. Our Types of communication the fi...
  • Page 3: The Difference Between Wired And Wireless Installations

    / of, time power of the RF module (integrated in the components) 25 mW. This brings great results applied across the fre- delay the lights and reset or adjust these functions at quency range of installations.
  • Page 4: Frequency 433 Vs. 868 Mhz

    489 directive RTTE, NVč.426 / cy band. 2000Sb (directive 1999 / ES). • off er (in the form of an iNELS checklist ) With the maximum radiated power relating to the distance at which these devices can communicate. FCC certifi cation is a condition...
  • Page 5: What Components Inels Rf Control Off Ers

    Installation manual iNELS RF Control Installation manual iNELS RF Control 3.3 What components iNELS RF Control off ers Controllers Lighting RFWB-20/G RFWB-40/G RF Key RF Pilot RFIM-20B RFIM-40B RFSG-1M RFSOU-1 RF-RGB-LED-550 RF-White-LED-675 2-button wireless 4-button wireless 4-button controller Wireless remote...
  • Page 6: How To Read The Type Designation

    It is recommended to use the suitable if you want to keep the existing control but- RF test pilot for this, because it is a fl exible control- ton and combine it with wireless - this can be done Location of the components depends on the distance ler and battery-powered.
  • Page 7: What Can Interfere With Rf Communication

    fl at base to mount on an existing installation box or stick to practically any material, even on glass. The RF Touch system controller is off ered with a wall box mounting (in case of 230 V). It is possible to...
  • Page 8 Installation manual iNELS RF Control Installation manual iNELS RF Control A real example of the range of RF Touch in a house where it was set to command „Scenes“ for switching 20 compo- What is the optimal signal passage? nents The fi rst house is built of bricks, the depth of the wall is about 20 cm.
  • Page 9: When To Use A Repeater

    3.8 When to use a repeater 4. CONNECTION COMPONENTS FOR LOAD SWITCHING / OUTCOMES If the RF Pilot displays a weak signal range (less than zanine, so that it can allow the signal to bypass the 30%), but it s not possible for the installation compo- metal barrier and arrived at the component.
  • Page 10 Check out the following summary table of the lamps load capacity: RF) using a delayed shutdown with a time of 5 min- Conversely, when although the valve is open, tem- utes.
  • Page 11: Switching Components

    RFSA-11B 1. Assignment of transmitter controls Each switching, dimming, shutter component can be controlled by a 32 channel controller (RF Key, RFWB- Function 4 - Impulse relay 20/40 RFIM-20/40 RFSG-1M). When one channel The output contact is switched to the opposite posi- represents a single button on the remote control.
  • Page 12: Dimming Components

    8 seconds (until double fl ash- t=2s..30min and further short pressings switch on / off the light button on the RF remote control, which is assigned ing LED disappears), then short press programming to this intensity. to a function. This set time interval is stored in the button to confi...
  • Page 13 Be sure to use the installation manual, which presents Maximum load of the eLAN-RF system unit able for activating GSM) a list of the installation components It is part of the RF < 1s - Max number of actuators - 40 (maximum of 70 (not PROG Pilot and RF Touch manual.
  • Page 14 Installation manual iNELS RF Control Installation manual iNELS RF Control How to connect the BUS version of iNELS? iHC-MIRF iHC-MARF iHC-TI iHC-MI iHC-TA iHC-MA iMM Client iMM Client iMM Client (Videozone 1) iMM Client (Videozone 2) iMM Client (Videozone 3) ...
  • Page 15: What Else You Should Know When You Install

    The following procedure uses equipment RFAF/USB, back on the state of the element within the system which is the standard off ered by ELKO EP and which units (RF Pilot, Smart RF box eLAN ... RF Touch, RF- 1. AXIS is lent to system integrators.
  • Page 16: Backup Parameters / Update Units Elan-Rf

    • When installing components RFDA-73/ (CZK) Database of brands can be found here: RGB (RGB strip) or RF RGB LED and sub- heating control (zone 3) 3 x RFSTI-11B 4737,- http://www.elkoep.cz/podpora/podpora-projekce/knihovnyznaek/ sequently controlling by RF KEY or wireless shutters (2)
  • Page 17 Installation manual iNELS RF Control Installation manual iNELS RF Control Examples in CAD (drawing) house, apartment, hotel room. Flat / Apartment RF Control Family Home RF Control R FSA-11 B Legend: RFWB-20/G RFWB-40/G RFSA-11B/RFSA-61B RFDA-71B RFTI-10B RFSTI-11B RFJA-12B/230V RF Touch...
  • Page 18: Why Sell Inels Rf Control

    Blinds and shutters other = one communication (RF Control). In • iNELS RF Control system is not a toy. Actuators allow the control of the event you have a “smart box” with mul- various types of shading. It is possible to set the time, modes, •...
  • Page 19: Inels References

    Installation manual iNELS RF Control Installation manual iNELS RF Control 9. iNELS REFERENCES Since creating the iNELS system we performed more than 5,000 installations. Hyundai Promeko Chateau Shop Dior Wellness Chateau Showroom Smart Light Nošovice, Czech Republic Olomouc, Czech Republic Holešov, Czech Republic...
  • Page 20 ELKO EP Holding Russia Ukraine Poland Czech Republic Germany Austria Spain Hungary Slovakia www.elkoep.com rev.1...

Table of Contents