10W-30
Synthetic 5W-30
Inspect Engine Oil Level
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so
could result in death or serious injury.
Inspect engine oil level prior to each use, or
every 8 hours of operation.
1. Place generator on a level surface.
2. Clean area around oil fill, and oil drain
plug.
3. Remove oil fill cap and wipe dipstick clean.
See
Figure
4-1.
Figure 4-1. Engine Oil Fill
4. To check oil level, insert dipstick into oil
filler neck without screwing it in. See
ure
4-2.
Figure 4-2. Safe Operating Range
5. Remove dipstick and verify oil level is
within safe operating range.
6. Add recommended engine oil as neces-
sary.
NOTE: Verify oil level often during filling pro-
cess to ensure overfilling does not occur.
14
SAE 30
WARNING
7. Replace oil fill cap and hand-tighten.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.

Change Engine Oil

Accidental start-up. Disconnect spark plug wires
when working on unit. Failure to do so could result
000399
in death or serious injury.
When using generator under extreme, dirty,
dusty conditions, or in extremely hot weather,
change oil more frequently.
NOTE: Don't pollute. Conserve resources.
Return used oil to collection centers.
Change oil while engine is still warm from run-
(000139)
ning, as follows:
1. Place generator on a level surface.
2. Disconnect the spark plug wire from the
spark plug and place the wire where it
cannot contact spark plug.
3. Clean area around oil fill and oil drain plug.
4. Remove oil fill cap and wipe dipstick clean.
Screw funnel into oil fill opening. See
ure
000804
Figure 4-3. Oil Fill Opening With Funnel
Fig-
5. Tip unit and drain oil completely into a suit-
able container.
6. Once oil is sufficiently drained from unit, tip
unit back to a level position.
7. Add recommended engine oil as neces-
sary.
8. To check oil level, remove funnel and
insert dipstick into oil filler neck without
screwing it in. See
9. Remove dipstick and verify oil level is
within safe operating range.
NOTE: Verify oil level often during filling pro-
cess to ensure overfilling does not occur.
001792
10. Replace oil fill cap and hand-tighten.
11. Wipe up any spilled oil.
12. Properly dispose of oil in accordance with
all applicable regulations.