Information in this Operation Manual is subject to change without notice due to correction or enhancement. The information described in this manual is the property of Western Scale Co. Ltd. No part of this manual may be reproduced or retransmitted in any form without the expressed written permission of Western Scale Co.
Digital Indicator INTRODUCTION The MAX digital weight indicator has been specifically designed for mobile weighing applications. Multiple power inputs, a versatile display, and a weather- proof enclosure allow for efficient and trouble-free scale operation in any location. Sophisticated filtering algorithms and display modes offer the best solution available for vibration issues and dynamic applications such as livestock weighing.
Operation Manual Features Mobile & Versatile • Large LCD display • Easy to read in low light and direct light conditions • Weather-proof, stainless steel enclosure suitable for outdoor use • MENU key accesses tickets and macro functions Multiple Power Inputs •...
Digital Indicator DISPLAY & ANNUNCIATORS The MAX uses a Liquid Crystal Display (LCD) with an LED backlight. HTN technology gives the display better contrast over wider viewing angles. LCD arrow and display annunciators communicate scale status and mode information to the user.
Operation Manual Display Annunciators Scale is weighing in POUNDS. Scale is weighing in OUNCES. Scale is weighing in KILOGRAMS. Scale is weighing in GRAMS. The weight on the scale is STABLE. The averaged scale weight has been LOCKED on the display (only if dynamic weighing is enabled).
Digital Indicator KEYPAD & SCALE FUNCTIONS The MAX indicator utilizes 5 keys for operator interfacing. To maximize indicator functionality, some keys perform multiple functions. MAX Keypad MENU - Cycles through the USER MENU to Press the key: access additional Scale Tickets and functions (See page 13).
Page 9
Operation Manual TARE - Acquires a tare value from weight on the Press the key: scale (Container, Box, etc.). The indicator will not tare if: • Scale weight is in MOTION; • Scale weight is zero, negative or over capacity; “Err 2”...
Digital Indicator INSTALLATION Pre-Installation It is always good practice to verify that your Western MAX indicator is complete and undamaged upon receipt. • Check over packaging for any signs of damage. • Remove the MAX from protective packaging and check for damage.
Digital Indicator OPERATION (WEIGHING MODE) Start-Up 1. Ensure AC, external 12 volt, or battery power is being applied. 2. Press and hold the ON/OFF key. 3. The indicator will perform a short start-up sequence including the software version number and a display segment test before entering Weighing Mode (displaying the scale weight).
Operation Manual Weigh Using a Tare (Containers, Pallets, etc.) 1. Ensure the weighing platform (scale) is empty and the indicator reads ‘0’. 2. Load the container on the scale and press the TARE key. The indicator will read ‘0’ and the NT annunciator (net weight) will be illuminated. 3.
Digital Indicator COMMUNICATIONS Scale communications with peripheral devices such as serial printers, remote displays and/or Personal Computers are configured by qualified Scale Service Technicians during scale set-up and calibration. Default Communications Settings: • 9600 Baud • 1 Stop Bit • No Parity •...
Operation Manual User Menu The User Menu gives the Operator access to additional scale tickets and/or indicator functions. 1. In Weighing Mode, press the MENU key to enter the User Menu. • User Menu options (tickets) are numbered by default as in Fig. A. •...
Digital Indicator Livestock Shrinkage The MAX features a livestock shrinkage program to compensate for potential “weight loss” experienced during transport. 1. Load the livestock on the scale. The actual weight is displayed. 2. Press the MENU key until “SHrinC” is displayed. Press ENTER to confirm.
Time & Date must be enabled and the format (12 Hr, 24 Hr, etc.) selected in Calibration Mode by qualified Technicians. If the MAX is disconnected from AC power or another power source, batteries must be installed for the clock to keep time.
Digital Indicator OPERATION (REMOTE DISPLAY MODE) The MAX may function as a Remote Display when connected to other Western indicators (Models M2000, MAX, Lightspeed & M1) by qualified Technicians. In Remote Display Mode, the MAX displays the connected indicator’s weight and scale status information.
Operation Manual Remote Keypad Functions Remote Display Mode utilizes the keypad to send serial commands for remote operation of indicator functions. To maximize functionality, some keys perform multiple functions. MENU – NO FUNCTION Press the key: ON / OFF – NO FUNCTION Press &...
Digital Indicator TROUBLESHOOTING & ERROR MESSAGES Unit won’t power up: When using D Cell batteries (or C cells in older versions) No Display: Press and HOLD the POWER key until indicator turns If the indicator does not turn on, verify the power source (power outlet, batteries, etc.).