  • Page 1 PNOZ X4 Safety relays Operating Manual 19894-EN-07...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Function Description Operating modes Timing diagram Installation Wiring Preparing for operation Operation Status indicators Faults – Interference Dimensions in mm Technical details Safety characteristic data Supplementary data Service life graph Order reference EC declaration of conformity Operating Manual PNOZ X4 19894-EN-07...
  • Page 4: Introduction

    PNOZ X4 Introduction Validity of documentation This documentation is valid for the product PNOZ X4. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    This gives advice on applications and provides information on special fea- tures. Safety Intended use The safety relay PNOZ X4 provides a safety-related interruption of a safety circuit. The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113‑1 and may be used in applications with E-STOP pushbuttons...
  • Page 6: Use Of Qualified Personnel

    Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120 VDC) are present on the unit, connected control elements and sensors must have a rated insulation voltage of at least 250 V. Operating Manual PNOZ X4 19894-EN-07...
  • Page 7: Unit Features

    The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Block diagram/terminal configuration Types: AC *Insulation between the non-marked area and the relay contacts: Basic insulation (over- voltage category III), Protective separation (overvoltage category II) Operating Manual PNOZ X4 19894-EN-07...
  • Page 8: Type: Dc

    III), Protective separation (overvoltage category II) Function Description The safety relay PNOZ X4 provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the feedback loop Y1-Y2 and the start circuit S33-S34 are closed.
  • Page 9: Timing Diagram

    Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing ele- ment (e.g. retaining bracket or an end angle). Operating Manual PNOZ X4 19894-EN-07...
  • Page 10: Wiring

    Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable runs, we recommend the following test after the installation of the device: 1.
  • Page 11: Preparing For Operation

    ESPE (only when U = 24 VDC) NOTICE With single-channel wiring the safety level of your machine/plant may be lower than the safety level of the unit (see Safety characteristic data [ 30]). Operating Manual PNOZ X4 19894-EN-07...
  • Page 12 NOTICE Operation with a light guard or safety switch It must not be possible to switch off the supply voltage for the PNOZ X4 separately from the supply voltage for the light guard or safety switch. E-STOP wiring, safety gate...
  • Page 13: Operation

    The safety functions may only be checked by qualified personnel. Status indicators LEDs indicate the status and errors during operation: LED on POWER Supply voltage is present. CH.1 Safety contacts of channel 1 are closed. CH.2 Safety contacts of channel 2 are closed. Operating Manual PNOZ X4 19894-EN-07...
  • Page 14: Faults - Interference

    Contact malfunctions: If the contacts have welded, reactivation will not be possible after the input circuit has opened. LED "POWER" does not light: Short circuit or no supply voltage. Dimensions in mm 75 (2.95") 45 (1,77") 87 (3.42") Operating Manual PNOZ X4 19894-EN-07...
  • Page 15: Technical Details

    40 mA 40 mA 40 mA Start circuit DC 70 mA 90 mA 90 mA Feedback loop DC 70 mA 90 mA 90 mA Min. input resistance at power-on 165 Ohm 165 Ohm 165 Ohm Operating Manual PNOZ X4 19894-EN-07...
  • Page 16 Max. current Max. power 2000 VA 2000 VA 2000 VA DC1 at 24 V 24 V 24 V Min. current 0,01 A 0,01 A 0,01 A Max. current Max. power 200 W 200 W 200 W Operating Manual PNOZ X4 19894-EN-07...
  • Page 17 Max. melting integral 240 A²s 240 A²s 240 A²s Blow-out fuse, quick 10 A 10 A 10 A Blow-out fuse, slow Blow-out fuse, gG 10 A 10 A 10 A Circuit breaker 24V AC/DC, characteristic Operating Manual PNOZ X4 19894-EN-07...
  • Page 18 70 ms 55 ms 55 ms With manual start max. 600 ms 350 ms 350 ms With monitored start typ. 40 ms 30 ms 30 ms With monitored start max. 70 ms 50 ms 50 ms Operating Manual PNOZ X4 19894-EN-07...
  • Page 19 Rated insulation voltage 250 V 250 V 250 V Rated impulse withstand voltage 4 kV 4 kV 4 kV Protection type Mounting area (e.g. control cabinet) IP54 IP54 IP54 Housing IP40 IP40 IP40 Terminals IP20 IP20 IP20 Operating Manual PNOZ X4 19894-EN-07...
  • Page 20 87 mm 87 mm Width 45 mm 45 mm 45 mm Depth 121 mm 121 mm 121 mm Weight 270 g 370 g 370 g Where standards are undated, the 2014-07 latest editions shall apply. Operating Manual PNOZ X4 19894-EN-07...
  • Page 21 Relay outputs 774735 774736 Number of output contacts Safety contacts (N/O), instant- aneous Auxiliary contacts (N/C) Max. short circuit current IK 1 kA 1 kA Utilisation category In accordance with the standard EN 60947-4-1 EN 60947-4-1 Operating Manual PNOZ X4 19894-EN-07...
  • Page 22 Utilisation category in accordance with UL Voltage 240 V AC G. P. 240 V AC G. P. With current Voltage 24 V DC Resistive 24 V DC Resistive With current Pilot Duty B300, R300 B300, R300 Operating Manual PNOZ X4 19894-EN-07...
  • Page 23 50 ms 50 ms Delay-on de-energisation With E-STOP typ. 15 ms 15 ms With E-STOP max. 30 ms 30 ms With power failure typ. 55 ms 55 ms With power failure max. 80 ms 80 ms Operating Manual PNOZ X4 19894-EN-07...
  • Page 24 PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 PPO UL 94 V0 Connection type Screw terminal Screw terminal Mounting type Fixed Fixed Operating Manual PNOZ X4 19894-EN-07...
  • Page 25 24 V 24 V Current at Input circuit DC 40 mA 40 mA Start circuit DC 90 mA 90 mA Feedback loop DC 90 mA 90 mA Min. input resistance at power-on 165 Ohm 165 Ohm Operating Manual PNOZ X4 19894-EN-07...
  • Page 26 Utilisation category In accordance with the standard EN 60947-5-1 EN 60947-5-1 Utilisation category of safety con- tacts AC15 at 230 V 230 V Max. current DC13 (6 cycles/min) at 24 V 24 V Max. current Operating Manual PNOZ X4 19894-EN-07...
  • Page 27 Ith per contact at UB AC; AC1: 240 V, DC1: 24 V Conv. therm. current with 1 con- tact Conv. therm. current with 2 con- tacts 7,5 A 7,5 A Conv. therm. current with 3 con- tacts 6,5 A 6,5 A Operating Manual PNOZ X4 19894-EN-07...
  • Page 28 Frequency 10 - 55 Hz 10 - 55 Hz Amplitude 0,35 mm 0,35 mm Airgap creepage In accordance with the standard EN 60947-1 EN 60947-1 Overvoltage category III / II III / II Pollution degree Operating Manual PNOZ X4 19894-EN-07...
  • Page 29 Torque setting with screw terminals 0,6 Nm 0,6 Nm Dimensions Height 87 mm 87 mm Width 45 mm 45 mm Depth 121 mm 121 mm Weight 370 g 370 g Where standards are undated, the 2014-07 latest editions shall apply. Operating Manual PNOZ X4 19894-EN-07...
  • Page 30: Safety Characteristic Data

    If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components. Operating Manual PNOZ X4 19894-EN-07...
  • Page 31: Service Life Graph

    PNOZ X4 115 V AC Screw terminals 774 735 PNOZ X4 120 V AC Screw terminals 774 736 PNOZ X4 230 V AC Screw terminals 774 738 PNOZ X4 240 V AC Screw terminals 774 739 Operating Manual PNOZ X4 19894-EN-07...
  • Page 32: Ec Declaration Of Conformity

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/support/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PNOZ X4...
  • Page 33 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...