Dunham-Bush M1 Installation, Operation & Maintenance Instructions
Dunham-Bush M1 Installation, Operation & Maintenance Instructions

Dunham-Bush M1 Installation, Operation & Maintenance Instructions

Dunham strip radiant panels

Advertisement

Quick Links

Dunham Strip Radiant Panels
Installation, Operation & Maintenance Instructions
Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD
023 9247 7700
UK:www.dunham-bush.co.uk

IDENTIFICATION

Introduction

This booklet provides guidance for site activities
necessary to prepare, install and commission
Dunham Strip radiant panels. The instructions apply
for standard product only; please study them
carefully before commencing any installation work.

Description

Dunham Strip comprises aluminium sheet panels
with steel pipe clamped to the upper surface. The
pipes are located in a groove in the panel to
maximise the physical interface between pipe and
panel, ensuring efficient heat transfer to the
radiating surface. The panels have a durable
coating of epoxy polyester powder, and are fitted
with insulation to minimise heat losses above the
panel.
Code position
1
Code
Code position
Code
1
M1
M2
M3
M4
2
15
30
45
60
3
MP
MS
MF
MG
HP
HS
HF
HG
Table 1:
Product description code for Dunham Strip - for specifying individual radiant panels.
info@dunham-bush.co.uk
Global:www.dunham-bush.com
2
Description
1 pipe Dunham Strip
2 pipe Dunham Strip
3 pipe Dunham Strip (comprising M2 and M1 panels)
4 pipe Dunham Strip (comprising M2 and M2 panels)
Nominal length 1.5m
Nominal length 3.0m
Nominal length 4.5m
Nominal length 6.0m
Medium series DN32 (1¼") pipe - plain ends
Medium series DN32 (1¼") pipe - screwed ends
Medium series DN32 (1¼") pipe - flanged ends - PN40 BS4504
Medium series DN32 (1¼") pipe - grooved ends
Heavy series DN32 (1¼") pipe - plain ends
Heavy series DN32 (1¼") pipe - screwed ends
Heavy series DN32 (1¼") pipe - flanged ends - PN40 BS4504
Heavy series DN32 (1 ¼") pipe - grooved ends
The insulation is retained by insulation backing
plates to complete the radiant panel.
A range of accessories are supplied loose, giving
flexibility in system design and configuration.
Accessories include hanging brackets, cover plates
and end closers

Sizes

The number of pipes and the nominal length of each
strip are identified by the figure number. A suffix is
added to signify the weight of pipe and type of pipe
ends. Dunham Strip is a modular system; M3
panels comprise M2 and M1 panels; M4 panels
comprise two M2 panels.
3
Document Ref:
138-000-001-A
January 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dunham-Bush M1

  • Page 1 Code position Code Description 1 pipe Dunham Strip 2 pipe Dunham Strip 3 pipe Dunham Strip (comprising M2 and M1 panels) 4 pipe Dunham Strip (comprising M2 and M2 panels) Nominal length 1.5m Nominal length 3.0m Nominal length 4.5m Nominal length 6.0m Medium series DN32 (1¼”) pipe - plain ends...
  • Page 2 Medium pipe Water content (l/m) Heavy pipe Water content (l/m) 1.02 0.93 2.04 1.86 3.06 2.79 4.08 3.72 Table 2: Water content per linear metre of M1, M2, M3 and M4 Dunham Strip Page 2...
  • Page 3 Cover plates cannot be used with MF or HF (flanged connection) type panels. Diagram 3: Cover plate CP1 for M1 Dunham Strip Diagram 4: End closer EC1 for M1 Dunham Strip COMMISSIONING Fill and vent the systems and pressure test in accordance with recognised practice.
  • Page 4 Diagram 5: M1 and M2 Dunham Strip - nominal length 1.5m Diagram 6: M1 and M2 Dunham Strip - nominal length 3.0m Diagram 7: M1 and M2 Dunham Strip - nominal length 4.5m Diagram 8: M1 and M2 Dunham Strip - nominal length 6.0m...