Garudan HVP- 60 SERIES Operation Manual page 29

Table of Contents

Advertisement

Available languages

Available languages

!\)
0
PARAMETER
CODE
(025.8T3)
(026.8T4)
(027. CT)
(028.$85)
(029.$89]
(030.8CC]
(031.SM8)
(032.BAR)
(033.8RC)
(034.8RN)
(035.BTS]
(036.BT6)
(037.SMP)
(038. PM]
(039. PS)
(040.WON)
(041. TM)
(042.FSM)
(043.FTM)
(044. PN]
(045. SP)
[046.DIR]
PARAMETER FUNCTION
Stitch balance for End Back-Tacking 3 ( BT3)
Stitch balance for End Back-Tacking 4 ( BT4)
Setting
lime
inlefluplion
at
eadl
section
end of Back-Tacking( CT)
15 stitches plus on Startt End Back-Tacking ( SB5)
0--99 stitches plus on Start I End Back-Tacking ( SB9 )
Added 1 sti1ch tolhe C segment of End Back-Tacking ( BCC)
Mode selection for Bar-Tacking ( SMB)
Bar-Tacking selection (BAR)
Setting stitches of Bar-Tacking ( BRC)
Setting seam times of Bar· Tacking ( BRN )
O=(ln1inited times)
Stitch balance for Bar-Tacking 5 ( BT5)
Stitch balance for Bar-Tacking 6 ( BT6)
Mode seleclion for Constant-Slitch sewing (Path Sewing ) ( SMP)
Constant-Stitch sewing selection ( PM }
Setting stitches for Section 1 of constant-stitch sewing
Setting stitches for Section
2
of constant-stitch sewing
Setting stitches for Section 3 of constant-stitch sewing
Setting stitches for Section 4 of constant-stitch sewing
Setting stitches for Section 5-F
Wiper function selection ( WON )
Timmer function selection ( TM )
Presser Foot UP/DOWN at intermidiate stop ( FSM )
Presser Foot UPIDOWN after trimming ( FTM )
Numbers of sewing piece ( PN )
Sewing speed ( SP )
Direction of motor rotation ( DIR )
RANGE
I
UNIT
1/4,112,314,1.0,11/4, 1112, 1
314,2.0sties
·114,·112,-314,1.0.-1114,·
·1112,-1314, sties
eveiy
1/4
stitch adjusted
0-990 ms
ON /OFF
0-99 stitches
ON /OFF
AIM/SU/SD
ON/OFF
0-99 stitches
0-15 Times
1/4,112,314,1.0,1114, 1112, 1
314, 2.0
stitches
·1/4,112,314,.1.0,.11/4,·
·1112,-1314,
stitches
e'/el)'
114 sli1ch adjusted
AIM
ON /OFF
0-250
Stitches
0-250
Stitches
0-250
Stitches
0-250
Stitches
0-250
Stitches
ON /OFF
ON /OFF
UP/DN
UP/ON
0-9999
CW/CCW
/;'.
DEFAULT
KEY
DESCRIPTION
..
2
C.D
BT3=0:1nvalid,
BT3=1-8:1ncrease stitches of forward seam
BT3=9-F: Increase stitches of reverse seam
1
C.D
BT4=0:1nvalid,
BT4=1-8:1ncrease stitches of reverse seam
BT4=9-F: licrease stitches offorward seam
50
B.C.D Corner stop timer. Valid only at SMS,SME,SMB setting SU I SD.
OFF
C.D
Additional 15 stitches are added to the Start and End Back-Tacking stitches.
0
C.D
Additional setting stitches are added to the Start and End Back-Tacking stitches.
ON
C.D
ON: Valid, OFF: Invalid
A : One shot
sewin~.
A
D
M : Control by peda , can stop at middle way.
SU:One shot sewing but motor stops at needle up by CT timer at end of each seam.
SD:One shot sewing but motor stops at needle down by CT timer at end of each seam.
OFF
C.D
ON: Perform, OFF: Not perform
Valid only when
4
C.D
One setting for all seams
the C-30 panel is
4
C.D
Setting the seam times of Bar-Tacking.
disconneted
4
C.D
BT5=0:1nvalid,
BT5=1-8:1ncrease stitches of reverse seam
BT5=9-F: Increase stitches of forward seam
3
C.D
BT6=0:1nvalid,
BT6=1-8:1ncrease stitches of forward seam
BT6=9-F: Increase stitches of reverse seam
M
C.D
A: One shot pattern
sewin~.
M: Manual control by peda or START signal (standing operation)
OFF
C.D
ON: Perform, OFF: Not perform
15
B.C.D
15
B.C.D Stitches setting of seam P1-PF
15
B.C.D
Valid only when the Operation Panel C-30 is diconnected
15
B.C.D and [038. PM] set ON
0
B.C.D
ON
C.D
ON: Perform, .OFF: Not perform
ON
C.D
ON: Perform, OFF: Not perform
ON
C.D
UP: At intermediate stop, presser foot
~oes
up
ON: At intermediate stop, presser foot eeps down
DN
C.D
UP: After Trimming stop, presser foot
~oes
up
DN: After Trimming stop, presser foot eeps down
0
Counting the products quantity.
0
Showing the current sewing speed.
ccw
C.D
CCW:Lockstitch, CW: Overlock, Interlock-stitch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents