ECO OPERATION
To automatically control room to save energy (except in DRY and FAN ONLY mode)
ECO
Press
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1 degree/
hour for 2 hours (maximum 2 degrees increase). For heating operation the set
temperature will decrease.
11
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or
stop without using the remote control.
Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
12
TIMER OPERATION
Set the timer when the air conditioner is operating.
Setting the ON Timer
1
Press
: Set the desired
ON timer.
2
Press
: Set the timer.
3
Press
: Cancel the timer.
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
1
Press
: Set the ON timer.
2
Press
: Set the OFF timer.
During the daily timer is activating, both arrows ( , ) are indicated.
Note:
Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.
13
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
The P mark displays.
3. Press
: Operate the preset operation.
14
AUTO RESTART OPERATION
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
15
QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
QUIET
Press
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling due to low sound features.
COMFORT SLEEP OPERATION
16
For comfortable sleep, automatically control air fl ow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
1118350215_EN.indd 3
1118350215_EN.indd 3
Setting the OFF Timer
Press
: Set the desired
OFF timer.
Press
: Set the timer.
Press
: Cancel the timer.
3
Press
.
Press
button during
4
the ( or ) mark fl ashing.
for 3 seconds to memorize the setting.
17
MAINTENANCE
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.
No benzine, thinner, polishing powder or chemically-treated duster.
Air fi lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air fi lter.
3. Vacuum or wash and then dry them.
4. Reinstall the air fi lters and close the air inlet grille.
SELF CLEANING OPERATION
18
(COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
30 seconds.
19
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated for 3
minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before blowing warm air.
3. Warm air control: When the room temperature reaches the set temperature,
the fan speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into the room.
When the outdoor temperature is too low, use another recommended heating
apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit where
it will not be subjected to snow drifts, accumulation of leaves or other seasonal
debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Heating
–15°C ~ 24°C
Cooling
–15°C ~ 46°C
Dry
–15°C ~ 46°C
20
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
Cooling or Heating is abnormally low.
The power main switch is
The filters are blocked with dust.
turned off.
The temperature has been set improperly.
The circuit breaker is
The windows or doors are opened.
activated to cut off the
The air inlet or outlet of the outdoor unit
power supply.
is blocked.
Stoppage of electric current.
The fan speed is too low.
ON timer is set.
The operation mode is FAN or DRY.
21
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. "00" will be shown on the display.
MODE
4. Press
during pushing
"00" will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
more 2 times within
Room
Temperature
Less than 28°C
21°C ~ 32°C
17°C ~ 32°C