MWDUC

Service Manual

Dimensions
MWDUC08AR
MWDUC10AR/MWDUC12AR
North America Air Conditioner
W (mm, inch)
H (mm, inch)
471
18.5
340
482
19.0
372
D (mm, inch)
13.4
400
15.7
14.6
545
21.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MWDUC08AR and is the answer not in the manual?

Questions and answers

Summary of Contents for Classic MWDUC08AR

  • Page 1: Service Manual

    North America Air Conditioner MWDUC Service Manual Dimensions W (mm, inch) H (mm, inch) D (mm, inch) MWDUC08AR 18.5 13.4 15.7 MWDUC10AR/MWDUC12AR 19.0 14.6 21.5...
  • Page 2 ❺ Timer Button Operation Modes Press to start or stop the Auto On or Auto Off Instructions function. Press or hold either Up or Down the 1.1 Display control ❶ On-Off Button setting time from 0.0 to 24 hours. ❻ Sleep Button Press to turn on or Press...
  • Page 3: Electronic Function

    ② Temperature switch signal from remote for 7 minutes, the unit will turn off Use this switch to setting the temperature for Cooling this function. mode. ⓬ Cancel Button ● On-Off switch Press this button to stop the time on or off function. If Use this switch to turn on or off the only set timer off, and the unit has been turn off, press unit, the unit will only running at...
  • Page 4 Press sleep button again, or use the remote Operation conditon control to set anything. Turn off the unit. (TA-Ts) ℉ compressor on It is time to turn off the unit, for timer off function. Example: compressor off with a delay of 1 minute When TA≤TS, compressor off When T1>TS+2℉, compressor on ...
  • Page 5 5 Installation and use notice 5.1 The inside should be higher than outside, to make sure that the water from evaporator will be easy to flow to the outside. and the water will be helpful to get more capacity and more EER. NOTE: Check that air conditioner is tilted back about H(tiled about 3°to 4°downward to the outside).
  • Page 6: Troubleshooting

    5.2 Cleaning filter Structure Damage. Problem Solution Wall plug disconnected. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit Air conditioner breaker. does not start Plug Current Device Tripped. Press the RESET button.
  • Page 7: Characteristic Of Temperature Sensor

    Air movement sound. This is normal. If too loud, set 39.2 28.3459 4.2126 Noise when unit to a slower FAN setting. 26.8778 114.8 4.0459 is cooling Window vibration - poor installation. Refer to 42.8 25.4954 116.6 3.8867 installation instructions or check with installer. 44.6 24.1932 118.4...
  • Page 8: Exploded View

    7 Exploded view Front panel assembly Rear separating Front panel Left linker of fan motor Air outlet frame Right linker of fan motor Panel frame Centrifugal fan Vertical vane I Volute shell (below) Louver holder Mid volute shell Vertical vane II Volute shell (above) Evaporator assembly Electronic control box assembly...
  • Page 9 Classic Industries, Inc. 7101 NW 43 Street Miami, FL 33166 sales@classicairconditioners.com...