Special mode setting button (for 2113CIE3/2113E2/E1C model)

b No.1 - 5, 7, 8 : Press the "Power operation ( X )" button to turn on the power while pressing both the buttons A, B and the button C at
the same time.
b No.6 :
Turn on the power, then press and hold down the A and B buttons for over 3 se
b No.9 :
Turn on the power, then press and hold down the A and B buttons for over 10 seconds.
No.
Mode
Version display
1
(μcom/DSP Error Display)
User Initialization mode
2
(Installer Setup settings are not
initialized.)
Factory Initialization mode
3
(Installer Setup settings are also
initialized.)
PANEL/REMOTE LOCK Selection
4
mode
5
Service Related Selection mode
6
Remote ID Setup mode
Mode for switching tuner frequency
7
step
(E2 model Only)
Installer Setup mode
8
(AVR-2113CIE3 model only)
9
NETWORK Initialization mode
TUNER PRESET CH –
Button A
Button B
STATUS
DIMMER
TUNER
TUNER
PRESET CH +
PRESET CH –
ZONE2
DIMMER
SOURCE
ZONE2
TUNER
SOURCE
PRESET CH +
ZONE2
DIMMER
SOURCE
STATUS
DIMMER
TUNER
DIMMER
PRESET CH +
ZONE2
TUNER
SOURCE
PRESET CH -
ZONE2
DIMMER
SOURCE
ZONE2 SOURCE
DIMMER
TUNER PRESET CH +
X
22
Button C
Firmware versions such as Main or DSP are displayed in
the FL Display. Errors are displayed when they occur. (Refer
to 23 page)
Backup data initialization is carried out.
(Installer Setup settings are not initialized.)
Backup data initialization is carried out.
(Installer Setup settings are also initialized.)
Selects to reject operations through panel buttons and the
master volume knob on the main unit and operations via
the remote control.
Selects the "Diagnostic mode" or "Displaying the protection
STATUS
history mode".
When using multiple DENON AV receivers in the same
room, make this setting so that only the desired AV receiver
operates. (Refer to 33 page)
Change tuner frequency step to FM:50kHz/200kHz
Access the Remote Maintenance mode via the internet.
Installer Setup is displayed on GUI/Option Menu.
b Refer to AVR_RemoteMaintenance_.pdf of SDI.
Initializes NETWORK related settings.