7.2.
When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-AVC" web-site in
"TSN system", together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
RFKZ0494
2
RFKZ0416
3
RFKZ0418
CAUTION-1. (When servicing FLASH TOP P.C.B.)
1. Be sure to discharge the E.capacitor on FLASH TOP P.C.B..
Refer to "HOW TO DISCHARGE THE E.CAPACITOR ON FLASH TOP P.C.B.".
The E.capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP P.C.B..
Table S1 Extension Cable List
Connection
FP9001 (MAIN) - CCD UNIT
FP9002 (MAIN) - LENS UNIT
PP9001 (MAIN) - PS8001 (FLASH TOP)
22
Form
45PIN 0.3FFC
41PIN 0.3FFC
30PIN B to B