FujiFilm DR-ID 670 Operation Manual

Medium-format film cameras
Table of Contents

Advertisement

DR-ID 670
Operation Manual
1st Edition : May 2013
897N102735
This Operation Manual describes details on how to operate the DR-ID 670 and
cautions to be observed when operating it.
After reading this manual, store it nearby the DR-ID 670 so that you can see it
whenever necessary.
For Safe Operation
System
Configuration
(Product Overview)
Basic Operation
Daily Inspection and
Maintenance
Appendix
Maintenance and
Inspection

Advertisement

Table of Contents
loading

Summary of Contents for FujiFilm DR-ID 670

  • Page 1 Inspection This Operation Manual describes details on how to operate the DR-ID 670 and cautions to be observed when operating it. After reading this manual, store it nearby the DR-ID 670 so that you can see it whenever necessary. 897N102735...
  • Page 2 897N102735 DR-ID 670 Operation Manual...
  • Page 3 It is intended for use in general projection radiographic applications wherever conventional screen-film systems or CR systems may be used. DR-ID 670 is a device that provides images, which diagnostic image process is not implemented, to image collecting console. It is not designed for mammography, fluoroscope, tomography or angiography.
  • Page 4 If you would like to receive such source codes, please contact FUJIFILM dealer or the service representatives at the agency from which you purchased this product. (Please be noted that any inquiries concerning the contents of source codes should be directed to original licensers of open source software.)
  • Page 5: Table Of Contents

    Charging the Battery Pack (Optional) for the Flat Panel Sensor ......3-6 3.1.7 Installing/Removing the Battery Pack (Optional) for the Flat Panel Sensor ....3-7 Starting Up and Shutting Down the DR-ID 670 ............3-8 3.2.1 Starting Up the DR-ID 670 ..................3-8 3.2.2...
  • Page 6 Appendix A Specifications Specifications ......................A-1 A.1.1 Reduced Equivalent (DR-ID 670) ................A-1 A.1.2 Power Supply Conditions ..................A-1 A.1.3 Environmental Conditions ..................A-1 A.1.4 Image Performance ....................A-1 Appendix Z Precautions for Exposure Precautions for the Automatic X-ray Detection Function ..........Z-1 Z.1.1...
  • Page 7: Chapter 1 For Safe Operation

    For Safe Operation Chapter 1 1.1 Safety Before using the DR-ID 670, read this section thoroughly to ensure that you use the product properly. Electric Shock Warnings and Cautions WARNING The power supply to the DR-ID 670 is AC100 to 240V.
  • Page 8 Otherwise, it may become damaged, causing fire or electric shock. If necessary, protect the flat panel sensor by covering it with a disposable bag. Explosion Warnings WARNING Because this equipment is not explosion-proof, do not use combustible and explosive gases near the equipment. 897N102735 DR-ID 670 Operation Manual...
  • Page 9 WARNING Make sure that the devices to be connected to the equipment are authorized for connection. WARNING When the DR-ID 670 is connected to X-ray equipment, make sure that the equipment complies with IEC 60601-1. 897N102735 DR-ID 670 Operation Manual...
  • Page 10 WARNING To ensure complete system isolation, never install any unauthorized accessories or other such items. When it is necessary to install authorized accessories or optional items, contact a FUJIFILM dealer. WARNING Keep equipment other than those used for patients out of their reach to ensure appropriate system isolation.
  • Page 11 Disinfectant ethanol is recommended for disinfection. Carefully read the instructions and cautions supplied with the disinfectant before use. For details on the disinfectant, contact a FUJIFILM dealer or the service representatives at the agency from which you purchased the disinfectant.
  • Page 12 (voltage, current and charging method) different from those specified by FUJIFILM Corporation, the battery pack may emit smoke, ignite, explode or leak fluid. ● When storing the battery pack (125N100050) for a long period, charge the battery fully, remove it from the flat panel sensor and then store it in a cool and dark place.
  • Page 13 No modification of this equipment is allowed. CAUTIONS Install the system in accordance with what is provided by IEC 60601-1-1:2000 and IEC 60601- 1:2005 Chapter 16. Contact a FUJIFILM dealer for installation and relocation (except the flat panel sensor) of the system. CAUTIONS Do not hit or drop the equipment.
  • Page 14 Equipment not suitable for use in the presence of a flammable anesthetics mixture with air or with oxygen or nitrous oxide. ● According to the mode of operation CONTINUOUS OPERATION 897N102735 DR-ID 670 Operation Manual...
  • Page 15: Electromagnetic Compatibility (Emc)

    1.2 Electromagnetic Compatibility (EMC) 1.2.1 DR-ID 670 DR-ID 670 consists of DR-ID 600MP, DR-ID 670MC and DR-ID 601SE/DR-ID 602SE/DR-ID 611SE/ DR-ID 612SE/DR-ID 613SE. This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601-1-2 (EN60601-1-2), Medical Device Directive 93/42/EEC.
  • Page 16 Guidance and manufacturer’s declaration - electromagnetic emissions The DR-ID 670 is intended for use in the electromagnetic environment specified below. The customer or the user of the DR-ID 670 should assure that they are used in such an environment. Emissions test...
  • Page 17 Guidance and manufacturer’s declaration - electromagnetic immunity The DR-ID 670 is intended for use in the electromagnetic environment specified below. The customer or the user of the DR-ID 670 should assure that they are used in such an environment. Electromagnetic environment -...
  • Page 18 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the DR-ID 670 is used exceeds the applicable RF compliance, the DR-ID 670 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the DR-ID 670.
  • Page 19 Recommended separation distances between Portable and mobile RF communications equipment and the DR-ID 670 The DR-ID 670 is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the DR-ID 670 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the DR-ID 670 as recommended below, according to the maximum output power of the communications equipment.
  • Page 20: Precautions In Using The Dr-Id 670

    1.3 Precautions in Using the DR-ID 670 This section describes the precautions in using the DR-ID 670. 1.3.1 Handling Handle the flat panel sensor carefully since it is manufactured with precision. If the flat panel sensor or the SE cable connector is hit or dropped or is subject to severe shock, it may be damaged.
  • Page 21: Before Exposure

    Do not use the flat panel sensor, which is communicating with the power supply unit in wired communication mode, for the radiographic examination stand equipped with an automatic loading function. Exposure plane of the flat panel sensor 1-15 897N102735 DR-ID 670 Operation Manual...
  • Page 22: During Exposure

    ● Do not use a solvent such as thinner or benzine, as it corrodes the outer surfaces. 1.3.5 Storage When the flat panel sensor is not in use, store the device in a place where it does not fall or drop. 1-16 897N102735 DR-ID 670 Operation Manual...
  • Page 23: Precautions Related To The Load Applied To The Flat Panel Sensor

    Excessive load is applied locally and the fl at panel sensor may be damaged. Spine board Flat panel sensor Even when the fl at panel sensor is used on a fl at fl oor or platform, it may be damaged if the applied load exceeds the limit. 1-17 897N102735 DR-ID 670 Operation Manual...
  • Page 24 1-18 897N102735 DR-ID 670 Operation Manual...
  • Page 25: Dr-Id 670

    DR-ID 600MP • The products in can be installed in patient environment. • DR-ID 670 consists of DR-ID 600MP, DR-ID 670MC and DR-ID 601SE/DR-ID 602SE/DR-ID 611SE/DR-ID 612SE/DR-ID 613SE. • An access point is used only in wireless communication mode. * The confi guration of the system varies depending on the country.
  • Page 26: Unit Names And The Functions

    2.2 Unit Names and the Functions Unit names and the functions of the DR-ID 670 are described below. Applied part Applied part Connector Connector Status lamp Status lamp Flat panel sensor Flat panel sensor (DR-ID 613SE) (DR-ID 601SE, DR-ID 602SE, DR-ID 611SE and DR-ID 612SE) * Exposure plane is shown in this figure.
  • Page 27: Locations Of Labels And Signs

    2.3 Locations of Labels and Signs Locations of labels and signs affixed to the DR-ID 670, and the relevant safety signs are shown below. 2.3.1 Locations of Labels Flat panel sensor (DR-ID 601SE) Flat panel sensor (DR-ID 602SE) Color Label...
  • Page 28 DR-ID 612SE Identification Label DR-ID 612SE CE Mark Label DR-ID 613SE Identification Label DR-ID 601SE/DR-ID 602SE/DR-ID 611SE/DR-ID 612SE Caution Label DR-ID 601SE/DR-ID 602SE/DR-ID 611SE/DR-ID 612SE DR-ID 613SE Radio Law Certification Label Radio Law Certification Label 897N102735 DR-ID 670 Operation Manual...
  • Page 29 Battery Cover Label Power supply unit DR-ID 600MP Caution Label 1 DR-ID 600MP Caution Label 2 DR-ID 600MP Caution Label 3 DR-ID 670 Rating Label For the types of connectable cables, consult a FUJIFILM dealer. <Left-hand side> <Rear side> Battery charger...
  • Page 30 DR-ID 670 Rating Label DR-ID 600MP Caution Label 1 DR-ID 600MP Caution Label 2 / DR-ID 600MP Caution Label 3 / DR-ID 613SE Caution Label 1 DR-ID 613SE Caution Label 2 Battery Charger Rating Label Battery Pack Rating Label AC Adapter (Battery Charger)
  • Page 31: Safety And Other Symbols

    EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources. For more information about waste, please contact FUJIFILM dealers. Year of manufacture Caution for local load...
  • Page 32 897N102735 DR-ID 670 Operation Manual...
  • Page 33: Chapter 3 Basic Operation

    Use only one access point. A communication error may occur if two units or more are used. 3.1.2 Number of the Connectable Flat Panel Sensors To enable the flat panel sensor, its ID needs to be registered in advance by a FUJIFILM dealer. Up to five flat panel sensors can be registered.
  • Page 34: Connecting/Disconnecting The Flat Panel Sensor Connector

    If the fl at panel sensor is used with the connector inserted incompletely, the fl at panel sensor may turn off. Connect/Disconnect the connector straight to the fl at panel sensor. If connected/disconnected at an angle, the connector may be damaged. 897N102735 DR-ID 670 Operation Manual...
  • Page 35: Inserting/Removing The Flat Panel Sensor Into/From The Radiographic Examination Stand

    CAUTIONS Before inserting/removing the fl at panel sensor into/from the radiographic examination stand, pull out the tray completely. Otherwise, the fl at panel sensor may be damaged. 897N102735 DR-ID 670 Operation Manual...
  • Page 36 Pull out the tray, push the cassette receive Connector downwards, and then remove the flat panel sensor. Push the tray back into place. Cassette receive Set the flat panel sensor to the upper part of the tray. 897N102735 DR-ID 670 Operation Manual...
  • Page 37 Position the connector of the flat panel sensor as shown in the figure below. Connector Cassette stopper Center mark When setting the flat panel sensor horizontally, position the connector as shown in the figure below. Connector 897N102735 DR-ID 670 Operation Manual...
  • Page 38: Changing The Direction Of The Flat Panel Sensor Connector

    3.1.5 Changing the Direction of the Flat Panel Sensor Connector The direction of the connector of the flat panel sensor can be changed, depending on how it is inserted into the radiographic examination stand. To change the direction, contact a FUJIFILM dealer. When shipped After changing the direction 3.1.6 Charging the Battery Pack (Optional) for the Flat Panel...
  • Page 39: Installing/Removing The Battery Pack (Optional) For The Flat Panel Sensor

    To remove the battery pack, perform the same procedure as Step (removing the battery cover). • To install the battery cover, perform the same procedure as Step (installing the battery pack) Battery lock release latches 897N102735 DR-ID 670 Operation Manual...
  • Page 40: Starting Up And Shutting Down The Dr-Id 670

    3.2.1 Starting Up the DR-ID 670 Press the ON side of the main switch of the power supply unit. Start up the DR-ID 670 with the initial settings properly made by our official dealer. 3.2.2 Shutting Down the DR-ID 670 Press the OFF side of the main switch of the power supply unit.
  • Page 41: Chapter 4 Daily Inspection And Maintenance

    4.1 Daily User Inspection and Maintenance During maintenance and inspection, strictly observe precautions contained in “Chapter 1 For Safe Operation” in this manual for you to use the DR-ID 670 under best conditions. 4.1.1 Periodical Inspection Inspection Every Three Months Using a vacuum cleaner, remove any dirt or dust accumulated in each unit of the equipment once every three months.
  • Page 42 897N102735 DR-ID 670 Operation Manual...
  • Page 43: Appendix A Specifications

    Specifications Appendix A A.1 Specifications Specifications of the DR-ID 670 are shown below. A.1.1 Reduced Equivalent (DR-ID 670) Peak reduced equivalent on the front panel of the flat panel sensor: 0.5 mmAl A.1.2 Power Supply Conditions Rated voltage : 100-240V ±10% ~ Input current : 1-0.42A...
  • Page 44 897N102735 DR-ID 670 Operation Manual...
  • Page 45: Appendix Z Precautions For Exposure

    High Sensitivity Mode. In case of using the High Sensitivity Mode, a white image might be obtained by a shock. Figure of an exposure for the subject covering the entire surface of the flat panel sensor 897N102735 DR-ID 670 Operation Manual...
  • Page 46: Precautions Related To The X-Ray Exposure Time

    Z.1.2 Precautions Related to the X-ray Exposure Time When delivering radiation, do not set the exposure time beyond the maximum limit specified for the flat panel sensor at the time of installation. Otherwise, vertical artifacts may appear in the image. 897N102735 DR-ID 670 Operation Manual...
  • Page 47: Other Precautions

    The DR-ID 670 is a digital X-ray detector designed for use both within and outside of a standard radiographic bucky. Radiation field can be set up to 14” 5 17” for the DR-ID 601SE/DR-ID 611SE, 17”...
  • Page 48: Precautions During Calibration

    If artifacts appeared in the image due to X-ray irradiation, perform a test X-ray radiography after waiting for more than 2 minutes and then restart exposure after confirming that the artifacts disappear. 897N102735 DR-ID 670 Operation Manual...
  • Page 49: Appendix O Use Of Optional Items

    The device is also used to keep the sensor upright when storing. For the external view and precautions, see “O.4 Cradle” (page O-4). 897N102735 DR-ID 670 Operation Manual...
  • Page 50: Using The Se Storage Case

    When storing the flat panel sensor in the SE storage case, place it with the exposure plane down. For details, see the illustrations below. Battery holder Battery holder pockets pockets SE storage case for 35 SE storage case for 43 (DR-ID 601SE/DR-ID 611SE) (DR-ID 602SE/DR-ID 612SE) 897N102735 DR-ID 670 Operation Manual...
  • Page 51: Using The Retaining Bracket For Mp

    O.3 Using the Retaining Bracket for MP Bolt Fixture Anchor Contact a FUJIFILM dealer for installation of the Retaining bracket for MP. 897N102735 DR-ID 670 Operation Manual...
  • Page 52: Cradle

    ● If any damage such as cracking, chipping or peeling is found on the Cradle, use it after repair. Otherwise, personal injury may result. Consult a FUJIFILM dealer for repair. ● If excessive force is applied to the Cradle, it may be damaged. Also, do not apply excessive force to the fl at panel sensor inserted in the Cradle.
  • Page 53: Maintenance And Inspection

    (3 hours and 30 minutes) The cycles of periodical maintenance and inspection and of parts replacement differ depending on the usage and the daily operation time. For details, contact us directly or our official dealer. 897N102735 DR-ID 670 Operation Manual...
  • Page 54 897N102735 DR-ID 670 Operation Manual...
  • Page 55 In other words, this device automatically discontinue transmission in case of either absence of information to transmitor operational failure. (This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.) 897N102735 DR-ID 670 Operation Manual...
  • Page 56 611SE, DR-ID 612SE, DR-ID 613SE is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Por medio de la presente FUJIFILM declara que el DR-ID 601SE, DR-ID Español 602SE, DR-ID 611SE, DR-ID 612SE, DR-ID 613SE cumple con los requisitos...
  • Page 57 ID 611SE, DR-ID 612SE, DR-ID 613SE megfelel a vonatkozó alapvetõ [Hungarian] követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Hér með lýsir FUJIFILM yfir því að DR-ID 601SE, DR-ID 602SE, DR-ID Íslenska 611SE, DR-ID 612SE, DR-ID 613SE er í samræmi við grunnkröfur og aðrar [Icelandic] kröfur, sem gerðar eru í...
  • Page 58 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. 897N102735 DR-ID 670 Operation Manual...
  • Page 59 Radio Law certification Label (for Morocco) (DR-ID 602SE) Radio Law certification Label (for Morocco) (DR-ID 611SE) Radio Law certification Label (for Morocco) (DR-ID 613SE) Jordan Radio Law certification Label (for Jordan) (DR-ID 601SE) Radio Law certification Label (for Jordan) (DR-ID 602SE) 897N102735 DR-ID 670 Operation Manual...
  • Page 60 Battery charger Rating Label AC adapter (Battery charger) Rating Label Australia, New Zealand and Mexico Battery Charger Rating Label (for Australia, New Zealand and Mexico) AC Adapter (Battery Charger) Rating Label (for Australia, New Zealand and Mexico) 897N102735 DR-ID 670 Operation Manual...
  • Page 61 897N102735 DR-ID 670 Operation Manual...

Table of Contents