Operating Notes

Daily, check the oil drip rate through the indicator. Fill the oil tank.
After the initial running in period, check the belt tension. Belt squeal denotes a loose belt that requires tightening.
Inspect the filter fitted to the inlet, regularly clean and renew the element when necessary.
Excessive discharge temperature for normal operation as indicated by the rise in temperature shown in the log book
indicates inadequate cooling, faulty lubrication or a dirty intake filter. The machine should be stopped and inspected.
Check the machine internally for wear every 10,000 running hours. (see Inspection and Service)
The blade depth should be checked after the initial 2,000 running hours and thereafter every 5,000 running hours for
wear and renew if the rubbing tips have worn to a depth of 67mm. (see Check Blade Wear).
Condensate if allowed to enter the machine can cause severe blade wear.
If adjustment of the oil drip rate is required (see lubrication).
If machine is on a standby service, run for a few minutes each week.

Stopping Procedure

Proceed as follows: -
i.
Trip out or Stop the drive motor.

Lubrication

Prime oil pipes prior to initial start and every time machine is
dismantled for service, as serious damage will occur if the
machine runs unlubricated. The lubrication system is a total
loss system, recycling of oil is not recommended
The recommended grade of oil is Shell Turbo T68 the typical
physical characteristics are shown above.
Oil feed rate per calibrated oil drip measuring device is shown
on the right. These are available from our spares department.
The feed rates can be increased/decreased pro-rata with
speed.
Oil pump adjustment
The pump is adjusted to the correct flow rate when despatched from our works. If it
found necessary to alter the oil feed, then proceed as follows using fig. 7:
1.
Remove the cover (1) to expose two pistons (2).
2.
Slacken off the locknuts (3) and adjust the feed as required.
To increase the flow, turn the two adjusting screws (4) clockwise, or anti-clockwise to
decrease.
Lubricator Maintenance
Refill the oil reservoir regularly to ensure that the oil level is not allowed to fall to a
point where air can be drawn into the oil pump. Use only clean, new oil of the
recommended grade. At least once a year, or if the machine has been out of use for a
long period, the oil pump must be thoroughly flushed out with petrol/kerosene to clear any oil residues that may have
solidified in the control ducts. For this operation we recommend the following procedure: -
1.
Stop the machine and disconnect all the oil pipes from the oil pump.
2.
Remove oil reservoir, drain oil and wash out with petrol/kerosene. Drain again ensuring all oil residues are
removed. Replace reservoir and reconnect the oil feed pipe (oil reservoir to oil pump).
3.
Fill the reservoir with petrol/kerosene to cover oil filter element. Loosen oil feed pipe connection at oil pump end
until all air has been expelled. Re-tighten pipe.
4.
Start the machine under no load condition and run until petrol/kerosene begins to flow from oil pump discharge
points. This operation takes approximately 10 – 15 minutes and providing the machine is run under no load
conditions, no damage will occur.
5.
Stop machine, drain oil reservoir and fill with recommended grade of oil. Ensure all oil pipes are primed. Reconnect
oil delivery pipes (oil pump to machine) and start up.
GAS COMPRESSORS / BOOSTERS  GAS & AIR MIXING SYSTEMS  AIR BLOWERS & VACUUM PUMPS
The Utile Engineering Co. Ltd.
Telephone: + 44 (0) 1933 650216 Facsimile: + 44 (0) 1933 652738 Email: sales@utileengineering.com
Operating Notes
Stopping Procedure
Lubrication
Shell Turbo Oil
Kinematic Viscosity
@ 40C cSt
100C cSt (IP71)
Viscosity Index (IP226)
Pour Point C (IP15)
Density @ 15C kg/l (IP160)
Flash Point (PMCC) C (IP34)
Demulsibilty Number max. (IP19)
Neutralisation Number mg KOH/g (IP139)
Model
L95HP
L130HP
L175HP
Oil feed rate per calibrated oil drip indicator using oil pump timing drive speed ratio 1:1
Irthlingborough, Northamptonshire, NN9 5UG, ENGLAND
9
Speed 900 Rpm
Speed 1400 Rpm
Air
Biogas
Air
7.25
9.00
11.25
9.00
11.25
14.00
10.75
13.50
16.75
www.utileengineering.com
T68
68
8.8
102
-6
0.876
210
210
0.15
Biogas
14.00
17.50
20.75
Fig. 7
Fig. 7
IC182