Download Print this page

Advertisement

Quick Links

DIGITAL THERMOMETER
TES-1306
INSTRUCTION MANUAL
TES ELECTRICAL ELECTRONIC CORP.
1. SAFETY INFORMATION
This instrument is a digital thermometer for use with any K/J-type
thermocouple as temperature sensor. Temperature indication
follows National Bureau of Standards and IEC584 temperature /
voltage tables for K/J-type thermocouples.
Read the following safety information carefully before
attempting to operate or service the meter.
Use the meter only as specified in this manual; otherwise, the
protection provided by the meter may be impaired.
Environment conditions
 Altitude up to 2000 meters
 Relatively humidity 90% max.
 Operation Ambient 0 ~40℃
Maintenance & Clearing
 Repairs or servicing not covered in this manual should only be
performed by qualified personnel.
 Periodically wipe the case with a dry cloth. Do not use
abrasives or solvents on this instruments.
Safety symbols
Meter is protected throughout by double insulation or
reinforced insulation.
When servicing, use only specified replacement parts.
Comply with EMC

Advertisement

loading

Summary of Contents for TES TES-1306

  • Page 1  Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instruments. Safety symbols Meter is protected throughout by double insulation or reinforced insulation. When servicing, use only specified replacement parts. Comply with EMC TES ELECTRICAL ELECTRONIC CORP.
  • Page 2: Specifications

    2. SPECIFICATIONS Basic Accuracy: ( @23± 5℃ Calibration ) Accuracy are± ( ...% of 2-1 Electrical Specifications reading + degree ) at 18℃ to 28℃ with relative humidity up to 80% Measurement Range : Type J : Type K : For single thermocouple measurements -200℃...
  • Page 3: Name Of Parts And Positions

    the operating voltage. ( 32℉ to 64℉ and 82℉ to 104℉ ) Power Requirement: For each ℃ ( ℉ ) ambient below 18℃ ( 64℉ ) or above 28℃ 9-Volt battery , NEDA 1604 or JIS 006P or IEC6F22 ( 82℉ ), add to the accuracy specifications: Battery Life (typical): 100hours ( Alkaline Battery ) 0.01%...
  • Page 4: Recalibration Procedure

    If hold this key 2 seconds the meter will be back to the normal “MIN” "T1" , "T2" , "T1-T2" , "℃" , "℉" ,low battery " " etc. mode. 2). ON/OFF: The on/off key will turn the thermometer on and off. 8).
  • Page 5: Optional Accessory

    5. OPTIONAL ACCESSORY TP-K02: Available for temperature measurement of liquid, gels or air. K ( CA ) type thermocouple. Model Range Tolerances Description with Teflon tape insulation. ±2.2℃or±0.75% -50℃ to 200℃ TP-K01 Maximum insulating Bead probe (±3.6℉ or ±0.75%) -58℉ to 392℉ temperature : 260℃...
  • Page 7 TES ELECTRICAL ELECTRONIC CORP. 7F, No. 31, Lane 513, Rui Guang Road, Neihu Dist. Taipei. Taiwan, R. O. C. Tel : (02) 2799-3660 Fax : 886-2-2799-5099 E-Mail : tes@ms9.hinet.net http://www.tes.com.tw June-2000-4...