K
RMC1
R114
75
+5V
REMOTE
SENSOR
STOP
S102
PREV
S103
FR
S104
STBY SW
S108
7G
6G
5G
Dp
Col
b
m
c
IC101 : PT6315
IC201 : CXP84632-323Q
IC301 : BA4560F
IC401 : BH7862FS
Q201-203,207,402,403
: KRC102S
Q204
:
KRA102S
Q205
:
KSC1845F
Q206
: KRC107S
Q301-303,305 : KRC231S
Q304
:
KRA107S
Q307
: KTC3205Y
Q308
:
KRC102M
D101
: B30-2664-08
D102-105,202,203,304
: 1N4148WS
D201,204,401-403
: 1SS133T
D301
: 1N4007
D302
:
MTZ9.1B
(Y) :
AC110-240V
50/60Hz
(J) :
AC100V
50/60Hz
1
DIGITAL LINE
SIGNAL LINE
GND LINE
+B
B LINE
B LINE
B
VF-S500
L
CAUTION: For continued safety, replace safety critical components only with man-
ufacturer's recommended parts (refer to parts list).
ponents. For continued protection against risk of fire, replace only with same type
and rating fuse(s). To reduce the risk of electric shock, leakage-current or resis-
tance measurements shall be carried out (exposed parts are acceptably insulated
from the supply circuit) before the appliance is returned to the customer.
The DC voltage is an actual reading measured with a high impedance type volt-
meter. The measurement value may vary depending on the measuring instruments
used or on the product. Refer to the voltage during PLAY unless otherwise speci-
fied; The value shown in ( ) is the voltage measured at the moment of STOP.
DOLBY and the double-D symbol are trademarks of Dolby Laboratories Licensing
Corporation. Noise reduction circuit made under license from Dolby Laboratories
Licensing Corporation.
4G
3G
2G
Col
M
N
indicates safety critical com-
1G
O
DVF-S500
MAIN (3/3)