Ethernet Configuration - NKE PROCESSOR REGATTA User Manual And Installation Manual

Provides the most accurate, dynamic and noise-free information
Hide thumbs Also See for PROCESSOR REGATTA:
Table of Contents

Advertisement

− the message « set an address in the Gyropilot in Menu/Configuration » is
displayed on the Gyropilot Graphic. It has not been initialized.
− The system boot must be fully completed before any node can request an
address to the Processor. Once the data is displayed on the TL25, allow another 10
seconds.
− Display the Main Menu (Menu principal) with the Page key of the Gyropilot
Graphic
− Choose Configuration and then Initialisation adresse with the navigation pad
1
1
− Accept with Ent,
− The following message is displayed «
Ent,
− The following message is displayed « liste» and the Gyropilot gets a node
number which will temporary be displayed.
− Press Page to exit.
WARNING
The List creation is a long process (30 secondes). Always wait until the PROCESSOR
REGATTA boot is completed (blue LED = 1 blip every 3 seconds) before asking for a new
node number.

5.4 Ethernet configuration

Depending on the network configuration on board your boat, several connection options
are possible between your Processor Regatta and the PC.
• Direct Ethernet connection:
The network cable is supplied with the Processor Regatta. It is a crossover cable that
allows direct connection to your PC.
to get an address press ENT», press
RJ45 crossover network cable
9
33-60-084-001 PROCESSOR REGATTA Manual