To change out the UL4000 tool to the 1/2" version, the following steps should be followed.
*NOTE: Do not attempt to use 1/2" clamps with 3/4" head. (Adapter change-out: 3-5 minutes)
1. Prior to separation from power drill, back off tension block assembly ½" from head unit. See page 7.
2. Detach tension body from the battery-powered drill by loosening the single tensioning bolt on the aluminum collar and
separating the two sections.
3. Remove the blade from head by removing two cap screws (M05787) from the top of the head. It is not necessary to
remove entire head from tool in order to remove blade. (Figure 1) Remove the ¾" adapter plate from the blade.
4. Align the ½" adapter plate (M09387) with the blade (M09787) so that the guide is facing up. Incorrect placement will
not allow bands to be inserted into the tool. (Figure 1)
Note: To convert tool back to ¾", replace ½" insert with ¾" insert (M09887) and follow same instructions.
Be sure to retain unused shear plate for later use.
5. Attach the blade and ½" adapter plate onto head using the two previously removed cap screws. These cap screws
must be tight to assure proper cut-off of clamp tails.
6. Re-attach drill to tension body making sure the drill and tension body are properly aligned, and tighten the single
adapter cap screw located on the aluminum collar.
7. This tool is not designed to work with traditional band and buckle designs. BAND-IT Ultra-Lok
used.
Optional ½" Insert
(M09387)
Orient as shown
Blade (M09787)
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
Blade Cap Screw
(M05787) Qty. 2
Figure 1
WWW.CABLEJOINTS.CO.UK
THORNE & DERRICK UK
www.BAND-IT-IDEX.com
TEL 0044 191 490 1547 FAX 0044 477 5371
TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK
Page 14 of 14
Ultra-Lok
¼" Ball (M06587)
Bearing Tip (M05387)
Figure 2
Document # P07886 Rev. L
BAND-IT-IDEX, Inc. 2010
UL4000
Tool
clamps must be
Blade (M09787)
© Copyright
All rights reserved

Advertisement

Table of Contents
loading

Table of Contents