6.10.2. EXPLANATION OF ANALOG GATE ARRAY (IC5 on the Analog Board)
Pin No.
Name
1
DGND
GND (Digital)
2
BREAK
Controls pulse dialing
3
MDMRX
FAX RX Signal ON/OFF
4
EX-HOOK
Detects EXT. TEL OFF-hook
5
DCN
Detects parallel TEL OFF-hook
6
H/S ALC
Control H/S Volume
7
NOT USED
8
E-RECALL
Controls earth recall relay
Improves wave form of pulse
9
P-SHORT
dialing
10
WR
Writes enable
11
RD
Reads enable
12
CS
Chip select
13
D0
Data In/Out
14
D1
Data In/Out
15
D2
Data In/Out
16
D3
Data In/Out
17
D4
Data In
18
RS
Resistor select
19
RESET
Reset this IC
20
DVDD
5V (Digital)
21
DGND
GND (Digital)
22
NOT USED
23
SENSCTR
Controls paper end sensor (PC9)
24
BLACK
Paper end sensor output
25
SD
Serial data from DTMF receiver
26
LINE-RLY
Controls line relay (RLY1)
Mutes control to speaker AMP
27
SP-MUTE
(IC3)
28
HOOK
Detects hook switch (SW4)
29
BELL
Detects bell signal
30
MDMSRX
SP-Phone RX Signal ON/OFF
31
MDMTRX
TAM RX Signal ON/OFF
32
PT-HOOK
Detects parallel TEL ON-Hook
33
NOT USED
34
DVDD
5V (DIGITAL)
35
A-OUT
RX signal output to DTMF receiver
36
NOT USED
37
NOT USED
38
SPOUT
Speaker AMP output
39
SPPROUT
Speaker PRE-AMP output
40
SPPRIN
Speaker PRE-AMP (-) input
Function
I/O Pin No.
O
O
I
I
I
----------
I
O
O
I
I
I
I/O
I/O
I/O
I/O
I
I
I
O
----------
O
I
I
O
O
I
I
O
O
I
----------
O
----------
----------
(Model KX-FP300E)
13
(Change from original page 161.)
Name
41
PROUT1
PRE-AMP1 output
42
AGND
GND (Analog)
43
RTONE
Not Used
44
RIN
Handset receiver AMP input
45
ROUT1
Handset receiver AMP output 1
46
ROUT2
Handset receiver AMP output 2
47
NOT USED
48
NOT USED
49
NOT USED
50
NOT USED
51
MICIN
MIC AMP input
52
HSMIC-
Handset MIC AMP (-) input
53
HSMICOUT
Handset MIC AMP output
54
HSMIC+
Handset MIC AMP (+) input
55
NL2IN
Side tone suppressing AMP input
56
NL2OUT
Side tone suppressing AMP output
57
NL2IN
Suppressing sensitivity adjustment
58
VREF
Reference voltage output
59
LINEIN
Line RX-AMP input
60
VCC
5V (Analog)
61
EXIN
EXT AMP input
62
EXOUT
EXT AMP output
63
LINEOUT
Line TX-AMP output
64
VREF2
Reference voltage output
65
ALCIN
ALC-AMP input
66
ALCDET
Attack/recovery time adjustment
67
PROUT2
PRE-AMP2 output
68
RECIN
Recording signal input
69
RECPRIN
Recording PRE-AMP input
70
RECPROUT Recording PRE-AMP output
71
LSRXOUT
SP-Phone MIC signal output
72
PLYOUT
Play AMP output
73
PLYIN
Play AMP input
74
LSTXOUT
SP-Phone speaker signal output
75
LSTXIN
SP-Phone speaker signal input
76
TONE IN1
DTMF monitor signal input
77
TONE IN2
Alarm/keytone input
78
TONE IN3
Ringing signal input
79
TONE IN4
Pulse dial monitor signal input
80
AGND
GND (Analog)
KX-FP300E
Function
----------
----------
----------
----------

Advertisement

loading