Hide thumbs Also See for DiaDENS-T:

Advertisement

JSC RC ART Ekaterinburg, Russia
Analgetic transcutaneous portable apparatus with built-in and external
electrodes for stimulation of BAZ and BAP, auricular and Voll's
diagnostics.
DiaDENS
[ Operations Manual ]
(888) 709-9457 www. jpastar .com
USA Distributor: JPA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DiaDENS-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JPA DiaDENS-T

  • Page 1 JSC RC ART Ekaterinburg, Russia Analgetic transcutaneous portable apparatus with built-in and external electrodes for stimulation of BAZ and BAP, auricular and Voll's diagnostics. DiaDENS [ Operations Manual ] (888) 709-9457 www. jpastar .com USA Distributor: JPA...
  • Page 2: Table Of Contents

    www. jpastar .com DIADENS (Operation manual) CONTENTS Function Main Performance Data Complete Set Component Parts and Operation Safety Measures General Recommendations Operating Procedure Technical Maintenance Certificate of Acceptance Guarantees Deficiency Reports Transportation and Storage Special Marks Therapeutic Action Indications Contraindications (general and relative) Methods of Application Instructions on Diagnostic and Therapeutic Modes Application...
  • Page 3: Diadens (Operation Manual)

    The apparatuses are made in two versions — DiaDENS-T and DiaDENS-DT. The DiaDENS-T version lacks auricular and Voll's diagnostics.
  • Page 4: Complete Set

    Operating manual including certificate External therapeutic electrode Diagnostic electrode Container Electric power source: Battery type 6F22 3.2 The complete set of delivery of the DiaDENS-T apparatus should correspond to Table 2. Table 2 Denomination Quantity DiaDENS-T electrostimulator Operating manual including certificate...
  • Page 5: General Recommendations

    www. jpastar .com DIADENS (Operation manual) 6. GENERAL RECOMMENDATIONS Treatment is fulfilled on the skin surface. Take a comfortable (lying or sitting) position and remove clothes from the parts of the body for electrostimulation. With the doctor's diagnosis treatment should be applied to areas indicated in he Operations Manual (see Supplement).
  • Page 6 www. jpastar .com DIADENS (Operation manual) STAND-BY mode in 2-5 sec. If a button is not pressed or there is no contact with the skin within 10 minutes, the apparatus announces "GOOD HEALTH", "GOOD BYE", and automatically switches off after a melody. MINIMAL EFFICIENT THERAPEUTIC DOSAGE PROGRAMME (MED) To enter MED press and release button FREQUENCY 5 ( + ) or 7 ( - ) (Fig.1, Fig.2) until the LCD shows the frequency value equal to 10 Hz (F10).
  • Page 7: Technical Maintenance

    www. jpastar .com DIADENS (Operation manual) Press button 3 ( B ) (Fig.1) to switch off the BIOREPER mode and switch over to the STAND-BY mode. VOLL mode (only for DiaDENS-DT) Press button 4( F ) to switch on the VOLL's diagnostics. (Fig.1). The passive electrode is taken into the free hand.
  • Page 8: Guarantees

    DIADENS (Operation manual) www. jpastar .com 10. GUARANTEES The manufacturer guarantees the compliance of the apparatus to the standards TU 9444-001- 41006303-2003 on condition the conditions of operation, transportation and storage are observed. The operation life-time is no less than 5 years. The guarantee period of operation is 12 months from the date of sale.
  • Page 9: Methods Of Application

    DIADENS (Operation manual) www .jpastar .com — individual intolerance to the electric current; — implanted cardiostimulator; — pregnancy (first trimester); — neoplasms of any etiology and localization*; — convulsive syndrome**; — acute febrility of unclear etiology (after emergency a special examination is needed including antiepidemic measures)**;...
  • Page 10 www. jpastar .com DIADENS (Operation manual) — apply sequential treatment to the required skin areas either in the "stable" mode or "labile" mode. The duration of the therapeutic action in one area makes on average 5 minutes. If during one treatment it is necessary to affect several areas (their number should not exceed 3-4 per treatment), it is permissible to increase the overall time of the treatment procedure.
  • Page 11 www. jpastar .com DIADENS (Operation manual) USER'S MANUAL FOR DIAGNOSTIC AND THERAPEUTIC MODES DiaDENS-DT diagnostic modes I. TEST mode TEST as the first phase of the MED therapeutic programme (see Section "Therapy") corresponds to the former notion of "dosed mode" and is used separately from the second phase to reveal latent trigger zones (LTZ).
  • Page 12 DIADENS (Operation manual) www jpastar .com — the active "point" electrode is set on the IN-TAN point which is located along the middle line of the head between eyebrows on the patient's nose bridge; — press button POWER 6 ( + ) (Fig.1) and hold it until the apparatus selects the individual testing voltage (the left lower part of the LCD shows 10 uA).
  • Page 13 DiaDENS-T diagnostic modes I. TEST mode (see DiaDENS-DT diagnostic modes) II. SCREENING mode (see DiaDENS-DT diagnostic modes) DiaDENS-T and DiaDENS-DT Therapeutic Modes I.THERAPY mode The THERAPY mode (in the manual for DENAS apparatuses it is named "constant mode") is switched directly at frequencies between 20-200Hz after the STAND-BY mode by pressing button «POWER»...
  • Page 14 DIADENS (Operation manual) www. jpastar .com II. MINIMALLY EFFICIENT THERAPEUTIC DOSAGE OF THE APPARATUS TREATMENT PROGRAMME (MED) The MED programme includes two phases. And operates only at 10 Hz. Automatic dosage is used. It is applied once during the course treatment in the required zones, with electrodes being fixed on the patient's skin for achieving a new level of adaptation, general resistance of the organism, prophylaxis of various pathological states (syndrome of chronic fatigue, seasonal indisposition, computer syndrome, epidemic period, hypopolivitaminosis).
  • Page 15 www. jpastar .com DIADENS (Operation manual)

This manual is also suitable for:

Diadens-dt

Table of Contents