Overhead Power Lines - McConnel PA96 Operator's Manual

Hedge cutter / grass mower
Table of Contents

Advertisement

OVERHEAD POWER LINES (OHPLs)
It cannot be stressed enough the dangers involved when working in the vicinity of
Overhead Power Lines (OHPLs). Some of our machines are capable of reach in excess of
8 metres (26'); they have the potential to well exceed, by possibly 3 metres (9' 9"), the
lowest legal minimum height of 5.2 metres from the ground for 11,000 and 33,000 volt
power lines.
Remember electrocution can occur without actually coming into contact with a power line
as electricity can 'flashover' when machinery gets close to it.
WARNING: All operators must read the following information and be aware
of the risks and dangers involved when working in the vicinity of
Overhead Power Lines (OHPLs).
Wherever possible the safest option is always to avoid working in areas close to OHPLs.
Where unavoidable, all operators must perform a risk assessment and implement a safe
procedure and system of work – see following page for details.
All operators should perform a risk assessment before operating the machine within 10m
horizontal distance of any OHPLs.
Minimum Heights for Overhead Power Lines
Absolute Minimum Exclusion Zones for Specific Overhead Power Lines