TEST AND MEASUREMENT
6.6.2.
Ramping Gain
The carrier power must be measured and calibrated for each power level at channel 62.
GSM 900
Power Level
(PL)
10
11
12
13
14
15
16
17
18
19
GSM 1800
Power Level
(PL)
10
11
12
13
14
15
Issue 1
Revision 0
Nominal
5
32.3
6
30.9
7
29
8
27
9
25
23
21
19
17
15
13
11
9
7
5
Nominal
0
29.05
1
27.8
2
26
3
24
4
22
5
20
6
18
7
16
8
14
9
12
10
8
6
4
2
0
Output Power (dBm)
Target
Min
Max
32.0
32.6
30.4
31.4
28.5
29.5
26.5
27.5
24.5
25.5
22.5
23.5
20.5
21.5
18.5
19.5
16.5
17.5
14.5
15.5
12.5
13.5
10.5
11.5
8.5
9.5
6.5
7.5
4.5
5.5
Output Power (dBm)
Target
Min
Max
28.8
29.3
27.3
28.3
25.5
26.5
23.5
24.5
21.5
22.5
19.5
20.5
17.5
18.5
15.5
16.5
13.5
14.5
11.5
12.5
9.5
10.5
7.5
8.5
5.5
6.5
3.5
4.5
1.5
2.5
-0.5
0.5
Section 6
– 42 –
Spec
Min
Max
31.8
32.8
30.0
31.8
28
30
26
28
24
26
22
24
20
22
18
20
16
18
14
16
12
14
10
12
8
10
6
8
4
6
Spec
Min
Max
28.8
29.3
27.0
28.8
25
27
23
25
21
23
19
21
17
19
15
17
13
15
11
13
9
11
7
9
5
7
3
5
1
3
-1
1
MCUK001002C8
Service Manual