Download Print this page
Pentair Pool Products WhisperFlo Pentair WhisperFloTM Pump Owner's Manual

Pentair Pool Products WhisperFlo Pentair WhisperFloTM Pump Owner's Manual

Pentair whisperflo pump owner's manual

Advertisement

READ AND FOLLOW ALL INSTRUCTIONS
SECTION I.
GENERAL INFORMATION ............................................................................................ 2
SECTION II.
MAINTENANCE ......................................................................................................... 3
SECTION III.
SERVICE .................................................................................................................. 5
SECTION IV.
RESTART INSTRUCTIONS ........................................................................................... 6
SECTION V.
TROUBLESHOOTING ................................................................................................. 7
SECTION VI.
TECHNICAL DATA ...................................................................................................... 8
A. REPLACEMENT PARTS ........................................................................................................ 8
B. PUMP CURVES .................................................................................................................. . 9
Before installing this product, read and follow all warning notices and instructions accompanying this pump.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call
(800) 831-7133 for additional free copies of this manual.
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
This pool pump must be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable local codes and
ordinances. Improper installation will create an electrical hazard which could result in death or
serious injury to pool users, installers, or others due to electrical shock, and may also cause
damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump.
Failure to do so could result in death or serious injury to serviceman, pool users or others due to
electric shock.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
Rev. D
6-5-01
WhisperFlo
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS

Table of Contents

Important Notice
Risk of electrical shock or electrocution.
Pump Owner's Manual
WARNING
WARNING
Listed
227T
1
Listed
P/N 071109

Advertisement

loading

Summary of Contents for Pentair Pool Products WhisperFlo Pentair WhisperFloTM Pump

  • Page 1: Table Of Contents

    Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. Pentair Pool Products 1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 Rev.
  • Page 2: Section I. General Information

    When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you must use a No. 8 AWG or larger conductor to connect to bonding conductor lug. To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked.
  • Page 3: Section Ii. Maintenance

    6. Permanently ground the motor using the green ground terminal located on the inside of the motor canopy or access plate, see Figure 1. Use the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground.
  • Page 4 THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
  • Page 5: Section Iii. Service

    SECTION III. SERVICE. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
  • Page 6: Section Iv. Restart Instructions

    B. Pump Reassembly/Seal Replacement; see Section V, Technical Data, Figure 4. 1. When installing the replacement shaft seal, use silicone sealant on the metal portion, before pressing into the seal plate. 2. Before installing the ceramic section of the seal into the impeller, be sure the impeller is clean.
  • Page 7: Section V. Troubleshooting

    B. Priming the Pump. 1. The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to prime the pump. a. Remove the pump lid plastic clamp. Remove the pump lid. b. Fill the pump strainer pot with water. c.
  • Page 8: Section Vi. Technical Data

    SECTION VI. TECHNICAL DATA. A. Replacement Parts. Item Part Model Description 357150 CLAMP POT (Black) 357199 CLAMP POT (Almond) 07-0795 P08080 COVER LEXAN AQ/WFE PUMP 357151 COVER LEXAN WFE PUMP 350013 O-RING WFE COVER 07-0387 P01325 BASKET AQ & WFE 07-0430 P02812 BOLT 3/8 16 X 1.15 HEX HD s/s, 4 req.
  • Page 9: Pump Curves

    B. Pump Curves. Single Speed Models Dual Speed Models SAVE THESE INSTRUCTIONS. Rev. D 6-5-01 P/N 071109...
  • Page 10 Also, Pentair Pool Products is not liable for any loss of time, inconvenience, incidental expenses such as telephone calls,...

This manual is also suitable for:

Whisperflo