Tab
Field
Title
Name
Basic Setup
Operation Mode
ON/OFF Indication
Color Setup
Image
ON Color
OFF Color
Option
Switch Sound
Display / Hide
Off
On
Valid Condition
Off (default)
On
Description
You can assign the configuration settings a name.
Bit Set: sets, i.e. turns on, the specified PLC bit device.
Bit Reset: resets, i.e. turns off, the specified PLC bit device.
Momentary: turns on the specified PLC bit device as long as the
switch part is pressed.
Alternate: reverses the status of the specified PLC bit device (ON or
OFF) each time the switch part is pressed.
Off: the switch's appearance does not change on the GT screen
even if you press it or the status of the output destination device
changes.
On: the switch goes on or off when you press the switch part or the
status of the output destination device changes.
 Push SW: the switch goes on or off only while you are pressing
it.
Device: the switch goes on or off based on the status of the
output destination device.
The check box "Assign Output Device" refers to the device
specified for the operation mode.
The image field displays what the part will look like with the current
settings.
Select the design for the part when it is ON.
Select the design for the part when it is OFF.
Select whether a sound is produced when a switch part is pressed.
The part is always displayed.
The part can be hidden and only displays under certain conditions,
which you define with [Setup] after activating this option.
 Relation Device: bit, word, word (unsigned), double word, or
double word (unsigned)
 Relation Code: for bit, set the device to ON or OFF; for word
and double word, select the desired comparative relationship,
e.g. =, >, etc. Depending on your selection, you may have to set
the corresponding values or select a device from which to read
the value.
Reference Device: define the device used as a reference for the
relation code.
The default setting for a part is "Always Operational".
Use [Setup] to define the conditions under which the part can be
used.
 Relation Device: bit, word, word (unsigned), double word, or
double word (unsigned)
 Relation Code: for bit, set the device to ON or OFF; for word
and double word, select the desired comparative relationship,
e.g. =, >, etc. Depending on your selection, you may have to set
the corresponding values or select a device from which to read
the value.
Reference Device: define the device used as a reference for the
5.1 Switch Parts