Rust staining

Advertisement

Alternate Repair Instructions
STEP 5
1. Completely cover the entire entry hub, the bond wire and the post clamp with two parts underwater epoxy
putty, (supplied with this kit), to at least 1/4 inch thickness.
a. If a bonding wire is connected to the bonding lug in the fixture housing cover this connection with a listed
potting compound, (Scotchcast 2134 or equivelant).
b. This will require the pool water level to be lowered and the potted area dried.
c. Allow 30 minutes prior to applying the epoxy putty.
2. Do not cover the anode block.
3. Allow the light fixture cord to move freely within the putty.
Cord must move freely within the putty to allow the removal of the light fixture should it ever need repair or replacement.
Potting
Compound
Rev. A 1-18-06
hn-09-11-16-98
NOTE
Do not cover
anode assy.
with potting
compound
Figure 5.
13