  • Page 1 Welcome to the Pureit Family REACH PUREIT AT +632-5620091 +632-9498071 www.pureitwater.com...
  • Page 3 India and abroad. If you need to get in touch with us for anything, please call us at +632-5620091, +632-9498071. We once again thank you for buying Pureit Marvella and we look forward to a long and fruitful association with you.
  • Page 4: Table Of Contents

    CONTENTS Unique features of Pureit Marvella .................3 Know your Pureit Marvella ..................4 Pureit Marvella’s Unique Technology ..............5 Water-flow Diagram & Electrical Circuit Diagram ...........6 Important usage instructions ...................7 Advance Alert System – LED Indicator Panel ...........15 Ordering CSF ......................16 Important instructions and precautions .............17 FAQs ..........................
  • Page 5: Unique Features Of Pureit Marvella

    UNIqUE FEATURES OF PUREIT MARVELLA Advance Alert System Alerts you before 150 Litres (approximately equal to 15 Days for a Household size of 5 members) of life left for CSF to get over High Intensity UV Lamp Powerful 11 W UV lamp for enhanced safety...
  • Page 6: Know Your Pureit Marvella

    80 psi. 4) In exceptional cases where the Input water pressure is less than 5 psi, you will need to install a pressure-boosting pump, at an extra cost. Please contact Pureit Call Centre for help.
  • Page 7: Pureit Marvella's Unique Technology

    PUREIT MARVELLA’s UNIqUE TECHNOLOGY X Ray View Ensures that no suspended particles enter the UV chamber High intensity UV rays ensure maximum UV intensity for inactivation of bacteria, virus and parasites to deliver safe water always Removes chlorine and organic impurities like harmful pesticides and remove parasites.
  • Page 8: Water-Flow Diagram & Electrical Circuit Diagram

    WATER-FLOW DIAGRAM Float Low Pressure Switch Diverter Ball Valve Pressure Feed Regulating Storage Tank Water ** Valve (PRV) Carbon Flow Restrictor Sediment Filter ** Operating Pressure Range 5 psi (Min) ~ 80 psi (Max) ELECTRICAL CIRCUIT DIAGRAM Float Switch 100 – 240 V AC UV Lamp 11W 50-60 Hz Solenoid Valve...
  • Page 9: Important Usage Instructions

    The water will be free of harmful germs, but there may not always be an improvement in taste. However by pouring brackish/sea water into the Pureit, there may be a risk of choking the system, and some of the components may malfunction.
  • Page 10 IMPORTANT USAGE INSTRUCTIONS Water CHANGE GKK CHANGE GKK Ensure the input water temperature is between 10° to 40°C. Do not connect the purifier to any geyser, heater etc. CHANGE GKK CHANGE GKK Avoid sharp bends to the tube that is connected to the purifier.
  • Page 11 IMPORTANT USAGE INSTRUCTIONS Install your Pureit Marvella away from the direct sunlight. Discard the first two cycles of water before you start using the purifier. Service technician may have to open the device and remove the flow restrictor Plunger if the input pressure is less than 10 psi.
  • Page 12 3) Purifier will not be installed in case input water line pressure is more than 80 psi. 4) In exceptional cases where the Input water pressure is less than 5 psi, you will need to install a pressure-boosting pump, at an extra cost. Please contact Pureit Call Centre for help.
  • Page 13 IMPORTANT USAGE INSTRUCTIONS Never splash the filtration system with water while cleaning. If the power cord is damaged, the power adapter must be replaced and not used.
  • Page 14 IMPORTANT USAGE INSTRUCTIONS Avoid using an extension cord. Do not install the purification unit where it could freeze.
  • Page 15 Do not allow any foreign or unexpected material to enter into the storage tank. The filtered water in the storage tank may deteriorate in the process. In case of any smoke or burning smell, remove the plug immediately and call the Pureit service centre.
  • Page 16 IMPORTANT USAGE INSTRUCTIONS When shifting your house, get the purifier duly inspected and packed by the Pureit service technician. Remove water from the storage tank and properly pack the purifier in case of shifting. You should only store water in the purifier and not use other bottles and containers.
  • Page 17: Advance Alert System - Led Indicator Panel

    ADVANCE ALERT SYSTEM – LED INDICATOR PANEL CHANGE CSF Call +632-5620091 +632-9498071 POWER ON/OFF TANK FULL No Light Power Off No Light Storage tank is filling Green Power On Solid Green Storage tank full PURIFICATION ON/OFF CHANGE CSF Blink Green UV Warming Time (45 Sec) Solid Green Solid Green...
  • Page 18: Ordering Csf

    CSF contains Sediment Filter and Activated Carbon Filter You can order CSF through following ways: By Calling Pureit Helpline +632-5620091 / +632-9498071 By Logging on to Pureit Website www.pureitwater.com Please call the Pureit helpline number to find out the current cost of the CSF...
  • Page 19: Important Instructions And Precautions

    IMPORTANT INSTRUCTIONS AND PRECAUTIONS Cleaning and Maintenance You can clean the tap by using disinfectants like Bleach/hypochlorite (50 ppm available chlorine). Discard 2 litres of water after cleaning the tap. SUPER DETERGENT POWDER External portion of the purifier must be cleaned using wet cloth only. Do not use detergent or soap. UV chamber is a sophisticated and specially designed mechanism.
  • Page 20 Precautions Always ensure to close off the ‘Ball valve diverter’ and switch off the mains, if you are out of home for long duration. Turn off the ball valve diverter and switch off the mains, if you notice any leakage from the purifier.
  • Page 21 Do not try to open the purifier for cleaning the storage tank. This can be done only by the qualified company personnel or authorised agent. 1). You can discard the water in the storage tank once in 15 days. 2). Always drain the water in the storage tank if you have not used the purifier for more than 2 days.
  • Page 22 Do not light candles on the purifier. Do not keep anything on top of the purifier. Do not allow any foreign or unexpected material to enter into the storage tank. The purified water in the storage tank may deteriorate in the process.
  • Page 23 Do not put heavy or sharp objects e.g. radio etc. on the purifier. Please ensure that the purifier is not installed near a cooking range. In case, UV Lamp breaks, carefully sweep all the fragments, wipe the area with a wet towel and dispose all the fragment including the used towel in a sealed plastic bag.
  • Page 24 08. Never buy Pureit Marvella or the Carbon Sediment Filter (CSF) from an unauthorised source. Remember all you have to do is call Pureit Helpline number and we will deliver a new CSF to you at your home for a minimal delivery charge.
  • Page 25: Faqs

    ‘Pureit Marvella’? First switch off the ball-valve if you find any leakage from ‘Pureit Marvella’ takes an average of 5 to 12 minutes to the purifier and turn off the power switch. Check for any purify 4 litres of water depending upon the input water visible improper fitment (like tap) and then call our Pureit pressure, water quality and remaining life of the CSF.
  • Page 26: Troubleshooting

    Please drain the stored water and fill fresh water. c. The CSF needs to be replaced/cleaned – Please replace or get them cleaned by calling the Pureit Helpline number. The purification is taking long time This might be due to one or more of the following reasons: a.
  • Page 28 Enteric Diseases (India) Setting benchmarks in water purification - India - Mexico - Indonesia - Brazil - Bangladesh Pureit is the - Nigeria world’s largest - Srilanka selling water - Kenya purifier brand - Ghana - Philippines 1 choice of families worldwide * Based on Unit shipment sales for 2012.

Table of Contents