Lacon L-EMM100CO Manual

10/100base-tx to 100base-fx

Advertisement

Quick Links

Managed Medi a Converter Chassis System

Preface

The Managed Media Converter Chassis System supports the Media Converter Chassis to
monitor the each Media Converter ( CO ) or Chassis Manager status and to configure
advanced function of the Managed Converter Chassis. Through Out-band management
via Web Browser utility to monitor/configure the Managed Media Converter Chassis
System.
This manual describes how to configure all Media Converter ( CO ), Chassis Manager and
each Managed Converter Chassis, which features eight slots of Meida Converters ( CO or
Chassis Manager ) in one Managed Converter Chassis, as well as the Remote side /
Terminal Media Converter ( CPE ).
The system allow to have 4 Managed Converter Chassis on one Managed System by
using IN/OUT Port for stacking, all you require to do is simply slide in one Chassis Manager
to any of Managed Converter Chassis in order to manage the system..
To get the most out of this manual, you should have an understanding of networking
concepts such as bridging, IEEE 802.3 10Base-T Ethernet, IEEE802.3u 100Base-TX/FX
Fast Ethernet and local area networks (LANs).
For more information about these topics, please refer to the Appendix.
1 User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L-EMM100CO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lacon L-EMM100CO

  • Page 1: Preface

    Managed Medi a Converter Chassis System Preface The Managed Media Converter Chassis System supports the Media Converter Chassis to monitor the each Media Converter ( CO ) or Chassis Manager status and to configure advanced function of the Managed Converter Chassis. Through Out-band management via Web Browser utility to monitor/configure the Managed Media Converter Chassis System.
  • Page 2: Table Of Contents

    Managed Medi a Converter Chassis System Table of Contents Preface Table of Contents Chapter Overview Technical Specifications System Configuration Application and Connector Pinouts Technical Specification Chassis Manager Media Converter ( MC ) as CO side Media Converter ( Terminal ) as CPE side 8 Slot Managed Converter Chassis System Configuration Connecting to Power...
  • Page 3: Chapter Overview

    Managed Medi a Converter Chassis System Chapter Overview Technical Specifications This chapter contains the following models: 1. Chassis Manager 2. Media Converter ( MC ) as CO side 3. Media Converter ( Terminal ) as CPE side 4. 8 Slot Managed Converter Chassis System Configuration This chapter provides network managers and system administrators with information about how to configure the Managed Media Converter Chassis System via the Web Browser.
  • Page 4: Technical Specification

    Managed Medi a Converter Chassis System Technical Specification Chassis Manager Key Features One-channel media conversion between 10/100Base-TX and 100Base-FX. Support AUTO-Negotiation and AUTO-MDIX for 10/100Base-TX Port. Fiber media allows: Multi-mode fiber using SC, ST, VF-45, MT-RJ, or LC connector Single-mode fiber using SC or ST connector WDM single-fiber ( bi-direction ) transceiver: Single-mode WDM fiber Using SC connector.
  • Page 5 Managed Medi a Converter Chassis System CPE MC Auto Report CPE MC Status – Status of power, Status of receiving optical power, Terminal link status, MC status, Informing way for optical receiving power off, Status of loopback test, Notification of link status for the terminal, Terminal link speed, Duplex for the terminal, Capability of auto-negotiation for the terminal, Number of interface in Terminal CPE MC Control - Forwarding Mode, Remote Control, Link Fault Pass Through,...
  • Page 6: Media Converter ( Mc ) As Co Side

    Managed Medi a Converter Chassis System 100Base-TX 2-pair UTP Cat. 5, up to 100m (328ft) 100Base-FX 50 or 62.5/125um Multi-mode fiber optic cable 9 or 10/125um Single-mode fiber optic cable Switching Method: Store-and -Forward Forwarding Rate: 14,880pps for 10Mbps; 148,810pps for 100Mbps Power Consumption: 4.2W Max.
  • Page 7 Managed Medi a Converter Chassis System Status LEDs. Used with a Managed Chassis. Hot-swappable when used with a managed chassis. Technical Specification LED: Per Unit – PW/FA (Power, Failure Alarm) Per Port – 10/100TX: LK/AT (Link/Activity), FD/CL (Full-duplex/Collision) 100FX: LK/AT (Link/Activity) Ethernet Standards: IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, 100Base-FX Cable: 10Base-T 2-pair UTP Cat.
  • Page 8: Media Converter ( Terminal ) As Cpe Side

    Managed Medi a Converter Chassis System Media Converter ( Terminal ) as CPE side Key Features One-channel media conversion between 10/100Base-TX and 100Base-FX. Support AUTO-Negotiation and AUTO-MDIX for 10/100Base-TX Port. Fiber media allows: Multi-mode fiber using SC, ST, VF-45, MT-RJ, or LC connector Single-mode fiber using SC or ST connector WDM single-fiber ( bi-direction ) transceiver: Single-mode WDM fiber Using SC connector.
  • Page 9: Slot Managed Converter Chassis

    Managed Medi a Converter Chassis System Physical Specification Power: 0.25A @ 12VDC Power Supply Operating Temperature: 0℃ ~ 45 ℃ (32℉ ~ 113℉) Storage Temperature: -10 ℃ ~ 70 ℃ (14℉ ~ 158℉) Humidity: 5 ~ 95%, non-condensing Emission & Compliance: CE Mark Class A, FCC Part 15 Class A Dimensions: 80mm (W) x 124mm (D) x 20mm (H) (3.15”...
  • Page 10 Managed Medi a Converter Chassis System Environmental Specifications Power: AC Input: 100-240V DC Input: 2.67A @ 12VDC Operating Temperature: 0℃ ~ 45 ℃ (32℉ ~ 113℉) Storage Temperature: -10 ℃ ~ 70 ℃ (14℉ ~ 158℉) Humidity: 5 ~ 95%, non-condensing Emission &...
  • Page 11: System Configuration

    Managed Medi a Converter Chassis System System Configuration Connecting to Power The chassis system is equipped with two power connectors. When the chassis is connecting with two powers, you can have the redundant function. AC power connector DC power connector AC 100V ~ 240V 2.67A @ 12VDC Chassis Stacking The Stacking function allows up to four chassis to be interconnected via their Stacking ports.
  • Page 12: Web-Based Browser Interface

    Managed Medi a Converter Chassis System Web-Based Browser Interface The Managed Media Converter Chassis System is accessible using a Web browser ( IE explorer, Netscape Communication, etc. ) to open up the Managed Converter Chassis monitering System. Logging on to The Managed Media Converter Chassis System The default IP Address for the System is ‘192.168.1.10 ’, and there is no need to type in both ‘...
  • Page 13: System Change

    Managed Medi a Converter Chassis System 1. System Change There are five items in the System Change menu : ‘ Device Name ‘, ‘ New Password ‘, ‘ Old Password ‘, ‘ Version ‘ and ‘ Mac Address ‘. 1.1. Device Name : This section is to set your own ‘...
  • Page 14: Ip Configuration

    Managed Medi a Converter Chassis System 2. IP Configuration There are 4 items in the IP Configuration : ‘ DHCP ‘, ‘ IP Address ‘, ‘ Netmask ‘ and ‘ Default Gateway ‘. 2.1. DHCP : To set the DHCP ‘ Enable ‘ or ‘ Disable ‘. 2.2.
  • Page 15 Managed Medi a Converter Chassis System Chassis => Chassis # 0~3 => Chassis H/W Monitor This section you can see the Chassis # 0~3 Hardware Monitor : Temperature. Supply Voltage Value ( 12 Volts ) : Suggest the normal condition 12 Volts ( +/- 10% ). Fan Status : There are 2 Fans in Chassis ( Status : ‘...
  • Page 16 Managed Medi a Converter Chassis System Operation Status : ‘ Normal ‘ or ‘ Local loop test ‘ or ‘ Far end fault ‘ or ‘ Hardware fault ‘ or ‘ Software fault ‘. Media Port 1 ( Type : Current Model ) : ‘ Link Status ‘, ‘ Receive Count ‘, ‘ Drop Count ‘, and ‘...
  • Page 17 Managed Medi a Converter Chassis System MC Options : Forwarding Mode : ‘ Store-Forward ‘ or ‘ Cut–Through ‘ or ‘ Repeater ‘ or ‘ Auto-Change ‘. Remote Control : ‘ Disable ‘ or ‘ Enable ‘. Link Fault Pass Through : ‘ Disable ‘ or ‘ Enable ‘. Media Port1 ( Type : Current Model ) : Port Mode : ‘...
  • Page 18 Managed Medi a Converter Chassis System 3.4. CPE MC AutoReport Chassis => Chassis # 0~3 => MC # 1~8 => CPE MC AutoReport Status of Loopback test : ‘ Not Test ‘ or ‘ Test ‘. Option B : ‘ Support ‘ or ‘ Not Support ‘. <...
  • Page 19 Managed Medi a Converter Chassis System Informing way for optical receiving power off : ‘ Far-End-Fault Pattern ‘ or ‘ Maintenance Frame ‘. MC support multi-port UTP : ‘ 1 ‘ or ‘ More Than 1 ‘. Link Fault Pass Through : ‘ Disable ‘ or ‘ Enable ‘. 3.5.
  • Page 20 Managed Medi a Converter Chassis System Capability of auto-negotiation for the terminal : ‘ Enable ‘ or ‘ Disable ‘. Number of interface in terminal : ‘ 1 ‘ or ‘ More Than 1 ‘. < NOTE > : If you wish to get the most recent remote status, please press the ‘ Apply ‘ button for the status.
  • Page 21 Managed Medi a Converter Chassis System Media Port2 ( Type : Current Model ) : Port Mode : ‘ 100HD ‘ or ‘ 100FD ‘. Flow Control : ‘ Disable ‘ or ‘ Enable ‘. Informing Way for Receiving Off : ‘ Far-End-Fault Patten ‘ or ‘ Maintenance Frame ‘. <...
  • Page 22: Monitor

    Managed Medi a Converter Chassis System Temperature : + 45 C Supply Voltage ( 2.5 Volts ) Supply Voltage ( 3.3 Volts ) Supply voltage ( 12 Volts ) < NOTE > : Under the normal condition, suggest the tolerance for all Supply Voltage should not exceed +/- 10%.
  • Page 23 Managed Medi a Converter Chassis System This section you can see the MC Status for all Media Converter installed in the Chassis . 4.2. Total CPE MC AutoReport Monitor => Chassis # 0~3 => Total CPE MC AutoReport This section you can see the Terminal MC Auto Report for all Media Converter installed in the Chassis.
  • Page 24 Managed Medi a Converter Chassis System 4.3. Total CPE MC Status Monitor => Chassis # 0~3 => Total CPE MC Status This section you can see the Terminal MC Status for all Media Converter installed in the Chassis . 4.4. Total Loopback Test Monitor =>...
  • Page 25 Managed Medi a Converter Chassis System This section you can see the Loopback Test Status for all Media Converter installed in the Chassis . 4.5. Total MC Hardware Status Monitor => Chassis # 0~3=> Total MC Hardware Status This section you can see the MC Hardware Status for all Media Converter installed in the Chassis.
  • Page 26: Snmp Configuration

    Managed Medi a Converter Chassis System 4.6. Chassis Monitor This section you can monitor all the 0~3 Managed Converter Chassis status. 5. SNMP Configuration 26 User Manual...
  • Page 27: Alarm

    Managed Medi a Converter Chassis System System Contact : Contact information for the system administrator responsible for managing system. System Location : Description of where your system is physically located. Get Community : public / private Set Community : public / private 6.
  • Page 28 Managed Medi a Converter Chassis System Low Power Limit (%) : 0 ~ 100 % High Temperature Limit (C) : Suggest set on 45 ℃ Fan Operation Time Limit (Hours) : 1000 Hours or more 6.3. Alarm Mail – Trap 28 User Manual...
  • Page 29: Save

    Managed Medi a Converter Chassis System If you check the « enable » Alarm by SMTP, system will send alarm information to the configured email address through the configured mail server. 6.4. Alarm SNMP – Trap SNMP enables network administrators to manage network performance, find and solve network problems.
  • Page 30 Managed Medi a Converter Chassis System If press OK for the ‘ Are you sure ? ‘ column, all changed configuration for Chassis Manager will be saved. And Cancel will be no save. 7.2. Configuration of all MC If press the save for configuration of all MC, all previous changes of configuration will be starting to save until it shows ‘...
  • Page 31: Default

    Managed Medi a Converter Chassis System 8. Default 8.1. Configuration of Chassis Manager If press OK for the ‘ Are you sure ? ‘ column, all configuration for Chassis Manager will be reset to factory default. And all configuration for Chassis Manager will not be reset to factory default if Cancel will be pressed.
  • Page 32: Update Firmware

    Managed Medi a Converter Chassis System If press the default for configuration of all MC, all configuration will be reset to factory default until it shows ‘ Done ‘. < NOTE > : Note the N/A indicate ‘ Not Applicable ‘. 9.
  • Page 33: Appendix A - Connector Pinouts

    Managed Medi a Converter Chassis System Appendix A - Connector Pinouts The following table lists the pinout of the Ethernet Switch ’ s 10/100Base-TX ports. For 10/100Base Pin 1 / 3 Trans / Receive Data + For 10/100Base Pin 2 / 6 Trans / Receive Data - 100BASE-FX: 100Mbp Ethernet implementation over fiber.

Table of Contents