Shutdown; Maintenance And Care; Troubleshooting; Oil Change - Kärcher HDS 801 E Manual

Hide thumbs Also See for HDS 801 E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
Warning
Frost will destroy the not completely water
drained device.
Store in a frost free area.
If it is not possible to store frost free, shut
down device.

Shutdown

For longer work breaks or if a frost free stor-
age is not possible:
Drain water.
Flush device with anti-freeze agent.
Empty detergent tank.
Dump water
Screw off water supply hose and high
pressure hose.
Unscrew closing stopper on the bottom
of the boiler and empty the boiler.
Operate device for max. 1 minute until
the pump and conduits are empty.

Maintenance and care

Danger
Risk of injury! Always disconnect the device
from the electrical power supply before per-
forming maintenance or repair work.
Warning
Only use original spare parts.
After each work, turn off device, refer to "Af-
ter each operation".
Set the appliance switch to "0".
Disconnect the main plug from the
socket.
Shut off water supply.
Activate hand spray gun until device is
pressure less.
Remove water connection.
Allow device to cool down.
Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.
16
English
Maintenance intervals
Before each use
Check the power cord with mains plug
for damage before every use. If the
power cord is damaged, please arrange
immediately for the exchange by an au-
thorized customer service or a skilled
electrician.
Check the high pressure hose for dam-
ages (risk of bursting). Please arrange
for the immediate exchange of a dam-
aged high-pressure hose.
Check the pump for leaks. If the leak-
age is more than 3 drops per minute,
call Customer Service.
Weekly
Clean the sieve in the water connection.
Clean filter at the detergent suck hose.
Check oil level.
In case of lacteous oil inform Kärcher
customer service immediately
After 500 operating hours, at least annu-
ally.

Oil change.

Oil change.
Ready a catch bin for appr. 1 Liter oil.
loosen release screw.
Dispose of old oil ecologically or turn in at
a gathering point.
Tighten release screw.
Fill oil slowly up to the MAX marking.
Note
Air pockets must be able to leak out.
For oil type refer to technical specifica-
tions.

Troubleshooting

Indicator lamp liquid softener glows
– Liquid softener tank is empty, due to
technical reasons a remainder stays in
the tank.
Refill.