Page 1
Installation/Owner’s Manual Series 1520 Series 1520 Series 1520 Stand Alone Card Readers or Controller Use this manual for circuit board 1505-009 Revision E or higher. 1520-065-E-7-16 26-Bit Wiegand Compatible, Time Zone Programmable, Transaction Buffer, Controls One Access Point Card Card Card Readers Readers...
TABLE OF CONTENTS SPECIFICATIONS Features Important Information 1520 Card Reader 1520 Controller SECTION 1 - INSTALLATION 1.1 Remove Components from Cabinet 1.2 Mount Cabinet 1.3 Re-Install Components into Cabinet 1.4 1520 Wiring SECTION 2 - PROGRAMMING 2.1 Re-Programming the Master Code 2.2 Relay Strike Time 2.3 Date and Time 2.4 Time Zones...
SPECIFICATIONS For 1520 Series with circuit board 1505-009 Rev E or higher ONLY. 1520 Card Readers 1520 Controller DK Prox Reader HID Reader AWID Reader P/N 1520-084 P/N 1520-082 P/N 1520-080 P/N 1520-081 Features • Memory size: 1000 card (device) codes.
Page 5
SPECIFICATIONS 1520 Card Readers P/N 1520-084 DK Prox Reader shown. Back Side Front Inside Enclosure Mounting Holes 1/2” 6.5” Knock-out Mounting Note: 4.5” 5.25” Can be mounted on a DoorKing gooseneck mounting post. 1520 Controller P/N 1520-081 Back Side Front Inside Enclosure 7.15”...
SECTION 1 - INSTALLATION Do not mount the 1520 card reader to a moving gate, or immediately next to a gate panel or pedestrian gate. Continuous vibration from slamming gates and vibration can cause damage to the system over time. WARNING! If the card reader is used to activate a vehicular gate operator, it must be mounted a minimum of 10 feet away from the gate and gate operator, or in such a way that the user cannot come into contact with the gate or gate operator...
1.2 Mount Cabinet Continued Controller Mounted Directly to a Wall or Pilaster Run ALL wires that will be needed during the cabinet installation and connect to 18-pin terminal. See Section 1.4 1520 Wiring. Use the 4 existing holes in the cabinet. Run conduit outside of wall or pilaster.
1.4 1520 Wiring 500 ft MAX Switch Input Postal lock connection. A switch closure DoorKing across terminals #7 and #14 activates Relay for its programmed strike time. Printer Adapter See Section 2.2 Relay Strike Time. P/N 1587-010 (Sold Separately) • Use any SERIAL printer with an RS-232 interface.
SECTION 2 - PROGRAMMING Before You Start Programming: IMPORTANT! Make sure the 1520 has power and we suggest that you become familiar with programming instructions before beginning any programming. 2.1 Re-Programming the Master Code The Master Code has been pre-programmed at the factory to 9999. This programming sequence re-programs the MASTER CODE if desired.
2.4 Time Zones There are two types of time zones that can be used with the 1520; CARD time zones and HOLD time zones. CARD time zones are applied to the individual card codes programmed into the system. HOLD time zones activate and deactivate the relay in the 1520 at predetermined times. There are SIX CARD time zones - referenced as time zones 0 through 5.
2.5 Card Code Programming In the following programming sequence, the term “card code” is also used to reference any 26-bit wiegand device code that is being used with the 1520. For example, digital entry codes or RF transmitter codes are also referred to as “Card Codes”. Card codes are always five-digits in length.
2.5.3 Delete a Single Card Code This programming sequence deletes a single card code and takes it completely out of memory to free up space for other card codes. Card codes not programmed in the 1520 will not print or be stored in the transaction buffer. If you want a transaction of denied card codes (for example - a lost card), then assign time zone 00 (always deny entry) in card programming 2.5.1.
2.7 Timed Anti-Pass Back The 1520 has a timed anti-pass back feature that will prevent a card code from being used within a period on time from the last use of the card code. To use the anti-pass back feature, you must set the time and date (section 2.3), set the pass back time (1 to 59 minutes) and turn the anti-pass back feature ON.
SECTION 3 - PRINT FUNCTIONS The table list the many different print functions that the 1520 can perform. After each function is complete, a long beep will sound. Keypad Entry Function 2 2 + master code Prints all card codes currently stored in the system memory. 0 6 + master code Prints all facility codes currently stored in the system memory.
3.2 Series 1520 Wiring Schematics 1520 Card Readers Green White P/N 1520-084 DK Prox Reader shown. Black Orange Gray External Lighting Built-In Card Reader MASTER CODE 1505-009 1505 1000 1520 Controller P/N 1520-081 MASTER CODE 1505-009 1505 1000 1520-065-E-7-16...
Page 16
Installation/Owner’s Manual Series 1520 Series 1520 Series 1520 Stand Alone Card Readers or Controller Use this manual for circuit board 1505-009 Revision E or higher. 1520-065-E-7-16 26-Bit Wiegand Compatible, Time Zone Programmable, Transaction Buffer, Controls One Access Point www.doorking.com DoorKing, Inc. 120 S.