Operation Manual Circle N, Suite 100 • St. Petersburg, FL 33716 USA 1000 112 (800) 451-9444 • +1 (727) 530-3602 www.Sensidyne.com • info@Sensidyne.com REF 360-0132-01 (Rev T, Software version 2.4.0)
Page 2
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page GilAir Plus Identifiers: A LCD Display B Status and Notification LED’s C Inlet Filter D Hi/Lo Control Valve E Charging Contacts F Belt Clip G Battery Access Screws H Power Port...
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Quality Policy Statement At Sensidyne, we are committed to providing products and services that consistently meet customer needs and comply with all applicable statutory and regulatory requirements. Our products are designed, manufactured and calibrated in accordance with ISO 9001:2008, ISO/IEC 17025:2005, ISO/IEC 80079-34, ATEX Directive 94/9/EEC, and IECEx, where applicable.
Gilian GilAir Warranty Sensidyne warrants that, at the time of delivery, the GilAir Plus shall be free of all defects in workmanship and material. Sensidyne will repair or replace, at its sole option, any GilAir Plus found to be defective by Sensidyne, if notified by Purchaser within the Warranty time period.
SECTION ONE: Preface Proprietary Notice The intended use of this manual is exclusive to owners of Gilian GilAir Plus air sampling pumps. The material within this manual is proprietary information and is to be used only to understand, operate, and service the instrument. By...
Page 10
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Disclaimer THE SELLER ASSUMES NO RESPONSIBILITY WHATSOEVER, TO ANY PARTY WHOSOEVER, FOR ANY PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH RECEIVED BY OR RESULTING FROM, IN WHOLE, OR IN PART, THE IMPROPER USE, INSTALLATION, OR STORAGE OF THIS...
UNDER NO CIRCUMSTANCES should this product be used except by qualified, trained and technically competent personnel. The GilAir Plus portable air sampling pump is intended for both indoor and outdoor use. The unit is not waterproof. NEVER submerge the unit in water. Pump failure, faulting or user injury may result.
Page 12
If the GilAir Plus pump comes into contact with a destructive substance(s) it is the responsibility of the user to take suitable precautions that prevent the pump from being adversely affected, thus ensuring that the Intrinsic Safety protection is not compromised.
2.1. Product Description The GilAir Plus is an advanced personal air sampling pump system available in three models: a basic model, a datalogging pump (DL) model, and standard temperature and pressure (STP) model. The STP model corrects the display flow rate and air volume to standard conditions of temperature and pressure.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 2.2. Pump Kit Descriptions Kits are available in one, three and five pump configurations, with power cords in US, Euro and UK versions. A matrix chart for the available kits are provided below.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir SECTION THREE: Set-Up 3.1. Preparation The package includes the pump, Dock, Dock power supply, and a line cord. The Dock serves as the charging base for all models and the communications Dock for the datalogging and STP models.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Dock position determination: When starting up on a Dock, the system pauses briefly to let the Dock provide the Dock position for use with the PC App. If no position is available after 45 seconds, a message appears asking the user to reseat the Dock.
3.4. Power Options The GilAir Plus comes standard with a rechargeable nickel metal hydride (NiMH) battery pack. The unit is charged through the Dock that is included with all starter kits. An optional alkaline battery pack (P/N 783-0013-01-R) is available that allows the use of over-the-counter AA batteries.
4.1. Overview The GilAir Plus has the capability of generating and controlling flow over the range of 20 cc/min to 5100 cc/min in two flow ranges, 20-445 cc/min, and 450-5100 cc/min, that are selectable using a 2 mm or 5/64 inch hex key (provided with the pump). The actual flow is measured and controlled by the pump’s internal processor.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 4.3. Navigation The GilAir Plus pump uses an intuitive six-button keypad for menu navigation and pump operation. The buttons and their functions are summarized in the table below. Symbol Name Function...
Page 21
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page General operation of the menu system: Access the menu by pressing the button. The menu is displayed in a vertical column. Some menu items have a ► sign after the menu item and lead to submenus. When the selected menu has the ►, pressing the button enters the submenu.
Description Menu Display The main menu allows all of the parameters of the operation of the GilAir Plus to be set, by scrolling to the appropriate menu item (Section 4.3. ) Idle Shown when the pump is not conducting an event or in the main menu, Idle...
Page 23
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Constant Pressure Displays Backpressure BP (inches water, mmHg, KPa, mbar), Run Time RT (minutes) and Projected Run Time PRT (hours) based on battery charge status and backpressure. Fault Displays Run Time RT (min), Fault Count...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 4.5.1. Display Details Date and time: Displayed in selectable format mm/dd/yy or dd/mm/yy Battery icon: The NiMH battery pack is identified by an "N" to the left of the icon, the AA replaceable pack is identified by an "A".
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Volume (L) - Sample volume: The total volume of the sample, always shown in liters, at ambient conditions. Run time (min) – Sample time in minutes. Datalog Events: Displays the number of events recorded, and the percentage of the storage area used.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 4.5.6. Fault Display Details RT - Run Time: Total pump ON time. Does not include Sensor calibrations, pauses or scheduled off time in programs. FC - Fault Count: Total number of faults that have resulted in suspension of sampling.
4.6. Sensor Calibration The GilAir Plus pump has a built in automatic sensor calibration feature which allows the pump to maintain an accurate stable flow rate by intermittently calibrating the pump’s flow sensor to establish the zero flow point. This routine occurs before starting,...
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page The recirculation valve is checked for proper position. If it is incorrectly positioned, a popup message will alert the user. If the valve is moved to the correct position, the event start evaluation will continue.
Page 30
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir IMPORTANT! – The above instructions apply only if no Password (Section 5.15. ) has been selected for the pump (the Password is set at the factory default value of 0, disabled).
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 4.8. Flow Set (cc/min) Flow Set allows the flow rate at which the pump will operate in constant flow control mode to be set. The allowable range is 20 cc/min to 5100 cc/min. Flow rates between 20 cc/min and 445 cc/min require the flow control valve to be set for low flow operation (Lo indicator is displayed in the bottom status line).
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir The illustration below shows the flow control valve in between the Hi and Lo flow positions, where the display shows Err, indicating an error. The pump will not operate unless the flow control valve is in the correct Hi or Lo position for the corresponding flow rate setting.
Gilian GilAir Page The GilAir Plus has a Pre-Cal/Post-Cal mode (See Section 5.3. ) accessible through the Set-up menu. This mode will record a Pre-Cal/Post-Cal value for each sample accessible through the PC interface and upon pump data review. Pre-Cal and Post-...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 4.9.3. Displayed Flow Calibration Calibrate allows the flow rate of the pump to be verified or adjusted to the desired operating point. The calibration will be stored and used in subsequent operation until the pump is recalibrated.
LED illumination during the pause. If fault retry is enabled (See Section 5.8. ), the GilAir Plus will attempt an automatic re-start after three minutes. During that time if the fault cause was corrected (e.g., user sat in a chair and pinched the connection tubing shut momentarily) the pump will resume sampling.
Page 36
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Several conditions can initiate a fault condition as described below: Flow Control Fault (fault code FC): If the pump is running in the Constant Flow Control mode, and the flow rate cannot be maintained within the constant flow rate specification, the pump will go into a Flow Fault, a fault caused by flow outside the specifications of the pump.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page SECTION FIVE: Options Setup ► 5.1. The Setup submenu has controls that adjust the basic operating parameters of the pump. To change the settings for each item in the Setup submenu: buttons to move the cursor ►...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Event ID 1 will now be displayed. Use the buttons to assign the event any unique identification number from 1 to 999,999. The keys can be used to accelerate the adjustment rate (see Section 4.4. ).
Page 39
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page When you are at Run in the Main Menu and press the button to start a sample run, the display shows a notification that Pre-Cal is selected. Press the button to continue to Pre-Cal or the to exit the event.
5.7. EN13137 The GilAir Plus has two fault detection modes, normal and EN13137. When EN13137 is enabled, a flow control fault will occur when the flow rate falls to zero for more than 120 seconds as specified in the EN/ISO13137 standard. Restart will not be attempted with this option.
SmartCal Automatic Calibration GilAir Plus has an optional automatic calibration capability called SmartCal. Select an air flow calibrator and connect it to the Dock using the appropriate communications cable. When active; Pre, Post and flow calibration can be performed automatically through the Dock.
The tubing setup is the same as a manual calibration (See Section 4.9.3. ). Using the SmartCal feature requires the GilAir Plus pump to be connected to the Dock with the cable to the calibrator plugged in.
Page 43
Connect the SmartCal cable to the PC Serial connector on the Gilibrator and the Reference Device port on the rear of the Dock. Using the GilAir Plus pump main menu, go to Setup ►SmartCal. Use the buttons to select Gilibrator. Press and release the button.
Verify the desired calibration flow rate is within the Challenger range. Select the appropriate range if necessary. The Challenger reads flow continuously and reports it for display on the GilAir Plus. When flow stability is reached, the calibration will be calculated and stored in the pump. Calibration Complete will be displayed. The button can be used to return to the main menu.
TSI™ Model 4146 and Sensidyne Go-Cal The TSI Model 4140/Sensidyne Go-Cal reads flow continuously and reports it for display on the GilAir Plus. When flow stability is reached, the calibration will be calculated and stored. Calibration Complete will be displayed. The button can be used to return to the main menu.
Data port on the Defender and the Reference Device connector on the rear of the Dock as shown in the photo. Set up the BIOS Defender to sample continuously. On the GilAir Plus pump, go to Setup, then SmartCal. Use the buttons to select BIOS Dfndr.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Before removing the pump from the Dock, press and release the button. Then remove the pump from the Dock, go to Run in the Main Menu, and press and release the button.
Standard Temperature (STP Models only) Users may set the temperature that will be used in the calculation of the standard flow and volumes when using a STP Model pump. The GilAir Plus factory default is 25°C (77°F) as the standard temperature.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page The cursor ► will now be at Std Temp (˚ C). Press and release the button to move the cursor ► to Std P (mmHg). The current setting for Std P (mmHg) will be displayed at the right side of the screen.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Display Options ► 5.13. These parameters control the appearance and format of displayed pump data. 5.13.1. Language Users may select the display language; languages available include: English, Spanish, French, Dutch, German, Italian, Portuguese and Turkish. English is the default.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 5.13.3. Pressure Units Set the displayed unit of pressure for backpressure to ˝H O, mmHg, KPa or millibar. To set the units in which pressure is displayed: At the Main Menu screen, use the buttons to move the cursor ►...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 5.14.2. Date To set the Date: At the Main Menu screen, use the buttons to move the cursor ► to Setup ►. Press and release the button. The pump will now display the Setup submenu screen.
5.15. Password The GilAir Plus offers a password protection feature. The password for unlocking the keypad can be set in this menu item. A password may consist of 1-4 numerals. If the password is set to 0, the password will not be required and the keypad will unlock without password entry.
Control Mode CF (Constant Flow), CPH (Constant Pressure High), CPL (Constant Pressure Low) The Control Mode determines which control parameter the GilAir Plus holds constant during the sample. The two control mode options are holding the flow constant or holding the pressure constant. Both control modes will operate in high flow and low flow.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Use the buttons to select either the CF (Constant Flow [20-5100 cc/min]), CPL (Constant Pressure Low [1-449 cc/min]) or the CPH (Constant Pressure High [450-5100 cc/min]) control mode. When the desired control mode is selected, press and release the button to complete.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Note: User programs will be listed as available Run Mode selections in addition to the Manual, Timed, Vol and RT modes, these can be selected the same way. Note: When the pump is powered on it will remember the last set Run Mode, Manual, Timed, Vol, RT or selected Program.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 5.19. Timed Duration Timed Duration specifies the how many minutes after the time specified in T/V/R start the event will end. The event starts as soon as the time has passed. If the T/V/R start time is set to 0:00 it will start immediately and use the current time as the start time.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir buttons to move the cursor ► to RT. Use the Use the buttons to set the time for the duration of the run in minutes. When the run time in minutes is selected, press and release the button.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page SECTION SIX: Programming Program ► 6.1. User programs specify a series of actions that control the sampling protocol employed by the pump. The pump can store up to 16 programs, each of which can be created, edited and executed.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir User selected or pump controlled off times will adjust the sampling time, but will not change the beginning or ending times. Pump controlled off times include Sensor Calibrations and fault pauses. User controlled off times are keypad initiated pauses.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 6.3. Program Name The program name is displayed when the Run mode is selected after a program has been entered and saved. When the program is entered on the pump, a name is assigned, i.e.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 6.6. Program Steps Each program step is numbered and executed sequentially. To enter or edit a program select the desired program step and edit it to perform the desired function. A program may have up to 20 steps.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page To set the Function for a particular program step: While in the Program Edit menu (section 6.2. ). buttons to move the cursor ► to Function. Use the Use the...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir If the program step you are entering/changing has the Date function assigned, use the buttons to set the date to the desired day. If the program step you are entering/changing has the Weekday function assigned, use the buttons to specify the desired day of the week.
Page 65
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page To Review the stored sample events: buttons to move the cursor ► to At the Main Menu screen, use the Review. Press and release the button. Use the buttons to select each sample event. There are eight lines of data for each event and the buttons switch between the pages.
Dock. This requires a special communications version Dock that is supplied in kits with the Datalog and STP pump models. The basic model of the GilAir Plus does not have this capability, nor will the basic Dock supplied with the Basic model pump support this option.
8.1. The Maintenance submenu has controls that are occasionally used. These functions are used for clearing the GilAir Plus pump memories, calibrating transducers or performing other pump maintenance functions. To change the settings for each item in the Maintenance submenu: buttons to move the cursor ►...
Page 68
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir To perform Global Reset: Note: To preserve user programs, go to the Reset menu item instead of Global reset. (See Section 8.2.1. ) buttons to move the cursor ►...
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 8.2.1. Reset (save programs) Resets all user control parameters to factory ship values while preserving users programs. To perform Reset (save programs): At the Main Menu screen, use the buttons to move the cursor ►...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir 8.2.2. Clear Datalog Clear Datalog erases all datalog entries. When the datalog is full, any data saved in subsequent events will be lost. The datalog should be cleared after the data is extracted to allow space for new events.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page T ambient Cal ► 8.3. Calibrates the ambient temperature sensor (available in STP version of the product). The calibration should be checked periodically, typically at the beginning of a sample run.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Barometric P Cal ► 8.4. Calibrates the barometric pressure sensor (available in STP version of the product). The calibration should be checked periodically, typically at the beginning of a sample run.
To perform Pressure calibration: Set up the GilAir Plus pump, load panel and reference meters as shown. For this procedure, the pump must be set to the Lo range of operation. During the calibration, the pump will run and maintain 35 inches of water backpressure.
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Once the GilAir Plus pump pressure is stable press and release the button to adjust the “Pressure” value to the pressure sensor reference meter reading. Press and release the button. The pressure display will return to the original display with the calibration changed.
All rechargeable batteries lose charge over time even if not in use. This is called self- discharge. The self-discharge rate of the NiMH cells used in the GilAir Plus battery pack is about 1% per day. It is important to have the pack fully charged when starting a sample.
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Enhanced electronic protection for the protective fuse in the battery pack.. When the battery charge becomes dangerously low, it is internally interrupted to slow the deep discharge of the pack. This will be reset when the pack is charged.
Page 77
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Replace the filter P/N 811-0905-01R. Be sure it is properly positioned and gasket seal areas are clear (Gasket P/N 300-0103-01R). Insert the filter housing in the manifold. Note the proper positioning of the two o-rings, P/N 150-9106-50 R and 150-9121-50 R (Replace if damaged).
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Appendix B: Example Program Setup & Edit This example program operates the pump as follows: The pump must be calibrated per Section 4.9.2. and 4.9.3. to run at a flow rate of 3000 cc/min.
Page 82
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir buttons to move the cursor ► to Value. Use the Use the buttons to set the hour to 16:00 or 4:00 PM. Press and release the button. Use the buttons to set the minutes to 00.
Page 83
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page buttons to move the cursor ► to Save. Press and release Use the button. Press the button 3 times to exit to the Main Menu. Use the buttons to move the cursor ► to Run Mode. Use the buttons to set the Run Mode to PROG01.
Page 84
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir To change the number of cycles in PROG01, access the Program Step where the Cycle function was entered. For the example program, the Cycle function was selected at Program Step 4.
Page 85
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Basic Program (similar to Timed mode) Program Starts at Pump Function Value Ends At Step Run Start Action Time 8:00 AM Run key 8:00 AM On Interval 480 (min.)
Page 86
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Day of week Program Starts at Pump Function Value Ends At Step Run Start Action Weekday Run key Next Monday Monday Time 8:00 AM 8:00 AM 12:00 AM On Interval 240 (min.)
Page 87
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page 5:00 PM 12:00 AM Time 8:00 AM Friday 8:00 AM 12:00 AM On Interval 8:00 AM 12:00 PM 12:00 PM 12:00 PM If this program is started anytime Tuesday to Sunday, it waits until midnight is past on Monday, waits until 8:00 AM, then turns the pump on until 12:00 PM (240 minutes, 4 hours) later.
Gilian GilAir Appendix C: Barometric Compensation The GilAir Plus barometric pressure compensation feature allows the pump to be moved after calibration to another environment with different temperature and pressure with a minimal effect on the ambient flow rate. This compensation is available for operation at flow rates from 450 cc/min to 5100 cc/min.
(e.g., lead) or asbestos fibers. With the Dual Port High Flow Manifold, the GilAir Plus can also accommodate one high flow and one low flow sample simultaneously (e.g., lead and benzene) using a filter cassette and a charcoal tube in tandem.
Page 90
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir For further information, see the GilAir Plus operations manual and the technical paper, GilAir Plus Quad Mode – Split Sampling in the High Flow Mode. PERFORMANCE SPECIFICATIONS Size dimensions, top access model....58 x 42 x 23 mm Size dimensions, bottom access model....
Gilian GilAir Page Appendix E: Troubleshooting Guide Symptom Possible Cause Corrective Action The GilAir Plus is seeing a back pressure less than 1 inch of water, an indication that no sample “Connect Media” train is connected. The Connect a sample train to the...
Page 92
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Symptom Possible Cause Corrective Action reset by shorting the charge terminals with a wire or paperclip. See Appendix H. Backlight on but Insufficient LCD drive Replace battery (Sec. 9.2. )
Page 93
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Symptom Possible Cause Corrective Action Valve dirty or torn Return for service Torn diaphragm on yoke Return for service assembly Tighten input manifold screws. Pump does not Tighten screws to snug tight only.
Page 94
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Symptom Possible Cause Corrective Action Pump stops Calibrate flow display occasionally and Flow display is out of restarts after 20 calibration (Sec. 4.9.3. ) seconds Wrong sample tube Displayed flow rate...
810-0902-01-R Datalogging Pump Only (No Dock) 810-0903-01-R STP Pump Only (No Dock) 910-0901-US-R GilAir Plus Basic Single Starter Kit, US cord 910-0901-EU-R GilAir Plus Basic Single Starter Kit, Euro cord 910-0901-UK-R GilAir Plus Basic Single Starter Kit, UK cord 910-0902-US-R...
Page 96
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Part Number Description 910-0904-US-R GilAir Plus Basic 5-Pump Starter Kit, US cord 910-0904-EU-R GilAir Plus Basic 5-Pump Starter Kit, Euro cord 910-0904-UK-R GilAir Plus Basic 5-Pump Starter Kit, UK cord 910-0905-US-R...
Page 97
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Part Number Description 811-0903-EU-R Single Station Dock w/Comms 100-240Vac, 50-60 Hz, Euro Cord (includes Power Supply) 811-0903-UK-R Single Station Dock w/Comms 100-240Vac, 50-60 Hz, UK Cord (includes Power Supply)
Page 98
Description 783-0014-01-R Battery Pack Bench Top DC Power Pack (for area sampling only). 811-0934-01-R Belt Clip w/ screws, GilAir Plus 811-0907-01-R Dock to PC, USB cable (w/inductor), for Com version Dock only 811-0905-01-R Inlet Filters, Replacement, Pack of 10 360-0132-01...
Page 99
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page Part Number Description 811-0919-01-R Dual Port High/Low Flow Manifold Kit only, Top Access with Tubing 811-0918-01-R Dual Port High/Low Flow Manifold Kit only, Bottom Access with Tubing 800165 Sorbent tube adapter nipple for Dual Port High Flow Manifold, ea...
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Appendix G: Specifications PERFORMANCE Flow Range………………….. 20 - 5100 cc/min (450 - 5100 cc/min in Constant Flow High Flow mode, 20-4459 cc/min in Constant Flow Low Flow mode) 1-5000 cc/min in Constant Pressure mode Flow Modes…………………..
Page 101
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page BAROMETRIC PRESSURE COMPENSATION (STP ONLY) Correction Accuracy....After calibration at the desired flow rate, the flow will not vary by more than 5% if the barometric pressure is in the range specified below.
Page 102
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir ENVIRONMENTAL Temperature Ranges Operating……………………… 32°F to 113°F (0°C to 45°C) Storage…………………….…. -4°F to 113°F (-20°C to 45°C) Charging…………………….. 41°F to 104°F (5°C to 40°C) Humidity Ranges Operating……………………. 5-95 %RH, non-condensing Storage……………………….
Gilian GilAir Page Appendix H: Charging/Communications Dock The Dock provided with the GilAir Plus charges the pump and optionally provides communications capability for a computer connection and connection to an air flow calibrator for automatic calibration (i.e., SmartCal). The Dock is available in one, three or five station basic or communication configurations.
Page 104
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir full charge in all cells in the battery pack. During the “top off” phase the green LED flashes slowly. At this point, the pump is at nominal full charge and can be removed and used, although it is recommended to wait for the “top off”...
Page 105
Plus Air Sampling Pump – Operation Manual ® Gilian GilAir Page DOCK VERSION 3.2, 3.4, 3.5, DISPLAY FOR NIMH BATTERY PACKS: (NORMAL CHARGE PROCESS) LED Indication Charge Status Dock: Brief red flashes every 2 sec Waiting for pump or battery to be inserted...
Page 106
Page Plus Air Sampling Pump – Operation Manual ® Gilian GilAir DETAIL INDICATIONS: (UNUSUAL CHARGE CONDITIONS) LED Indication Charge Status Dock: Continuous red Repeated analysis cycles, indicating deeply Pump: Red on long / short off discharged or damaged battery pack. Dock...
Page 107
The USB connection can be used to interface the pumps held on the Dock to a PC for use with the optional GilAir Plus PC Application. This application transfers event data to a PC database, provides pump management capability including the ability to copy pump setups and allows sampling plans (programs) to be created to control the timing and setting of pump operation.