Mitsubishi AG-150A Instruction Book

Centralized controller
Hide thumbs Also See for AG-150A:

Advertisement

Air-conditioner Network System
Centralized Controller
AG-150A
GB-50ADA-A
GB-50ADA-J
Before using the controller, please read this Instruction Book carefully to ensure correct
operation. Retain this manual for future reference.
(Web browser for optional functions)
Contents
1 Introduction .......................................................................... 1
1-1 Terms Used in This Manual .................................................... 1
1-2 Computer Requirements ......................................................... 1
control software (TG-2000A) .................................................. 1
2 Setting the Operating Environment ...................................... 2
2-1 Setting the PC IP Address....................................................... 2
2-2 Setting the Web Browser......................................................... 4
2-3 Setting the Java Execution Environment................................. 6
3 Performing Operations ......................................................... 7
3-1 Opening the Option Setting screen ......................................... 7
the outdoor unit..................................................................... 11
Instruction Book
WT05493X07
Ver.2.45/2.51

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi AG-150A

  • Page 1: Table Of Contents

    1 Introduction ................1 1-1 Terms Used in This Manual ............ 1 1-2 Computer Requirements ............1 1-3 Notes on using AG-150A with the integrated centralized control software (TG-2000A) ..........1 2 Setting the Operating Environment ........2 2-1 Setting the PC IP Address............2 2-2 Setting the Web Browser............
  • Page 2: Introduction

    Note: The use of the function of the outdoor units that measures the electric power will require the "Energy Management License Pack." Note: Use a security device such as a VPN router when connecting the AG-150A to the Internet to prevent unauthorized access. Note: "Booster unit" and "Water HEX unit" are referred to as "Air to water".
  • Page 3: Setting The Operating Environment

    2-1 Setting the PC IP Address Set an IP address on the PC that enables AG-150A to connect via a web browser. For instance, if the AG-150A IP address is [192.168.1.1], the PC IP address will need to belong to the same system [192.168.1.101].
  • Page 4 (4) In the [Internet Protocol (TCP/IP) Properties] dialog, click [Use the following IP address] and enter the IP address (for example, “192.168.1.101”) that you want to set in the IP address field. You normally set [255.255.255.0] as the subnet mask. Note: Ask your LAN administrator to provide the IP addresses and subnet mask.
  • Page 5: Setting The Web Browser

    2-2 Setting the Web Browser Use a security device such as a VPN router when connecting the AG-150A to the Internet to prevent unauthorized access. If no security devices are installed, the operation settings may be changed by an unauthorized person without the knowledge of the user.
  • Page 6 Note: If connecting to more than one AG-150A, you can specify multiple IP addresses like [192.168.1.1; 192.168.1.2], however, it is also possible to use the asterisk (*) and specify [192.168.1*].
  • Page 7: Setting The Java Execution Environment

    2-3 Setting the Java Execution Environment When using Java Plug-in version 1.6.0_10 or later, make the following environment settings (not required for version 1.6.0_09 or earlier). Note: The setting samples and screenshots used in this manual are those of Java Plug-in version 1.6.0_11. 2-3-1 Disabling the next-generation Java Plug-in (1) Open Java Control Panel by double-clicking Java in the Control Panel.
  • Page 8: Performing Operations

    Text below explains how to connect to the AG-150A and how to make various settings for the AG-150A. Note: If the AG-150A is restarted due to a power interruption etc., wait until the screen on the AG-150A main unit displays the normal operation screen (it takes several minutes before the normal operation screen is displayed) before using a web browser to access the AG-150A.
  • Page 9 AG-150A can encrypt communication data using HTTPS (SSL). When connecting the AG-150A to the LAN that can be accessed by the general public, it is recommended that the following settings be made so that the units are monitored and controlled on the encrypted Web page.
  • Page 10 (4) If the security alert has not been disabled, after entering the web address and hitting the Enter (Return) key, a security alert message will alert asking if you want to proceed. This is because the AG-150A uses the self-authentication system. Click [Yes] and proceed.
  • Page 11 [Enter] key on the keyboard. A screen appears for optional (measurement) settings. https : // [IP address of the AG-150A]/g-50/option.html Note: For example, type “https : // 192.168.1.1/g-50/option.html” if the AG-150A IP address is [192.168.1.1].
  • Page 12: Enabling The Function That Measures The Electric Power By The Outdoor Unit

    [Not Available] and cannot be changed to [Available]. Note: When connecting AG-150A controllers by connecting an Expansion Controller to the system, measurement settings should be made only on one of the AG-150A controllers.
  • Page 13 3-2-3 Setting the trend data format The data format to be used when the trend graph data of the measured value is downloaded can be set. (1) Select the separator character between [Comma ( , )] and [Semicolon ( ; )]. (2) Select the decimal point character between [Dot ( .
  • Page 14: Checking The Electric Power Measured By The Outdoor Units

    [Enter] key on the keyboard. A screen appears for login. http : // [IP address of the AG-150A]/administrator.html Note: For example, type “http : // 192.168.1.1/administrator.html” if the AG-150A IP address is [192.168.1.1]. Note: To encrypt data, change [http] to [https].
  • Page 15 3-3-3 Using a graph Click [Trend Graph] on the measurement condition list screen, and select the measured item to be displayed. The measured value can be checked by graph. The graph can also be downloaded as a CSV file. Overview display Click to display the measurement Update to most recent value as a list.
  • Page 16 Item Description Click [Download] to download the graph in the CSV format. The data format of the downloaded data is as follows. Item Format First line File type 124: Outdoor unit data yyyy/mm/dd Second line Date Note: The date format set on Initial Setting Web.will be applied. Temperature: "Address"...
  • Page 20 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/EC based on the following • Electromagnetic Compatibility Directive, EU regulations: 2004/108/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

This manual is also suitable for:

Gb-50ada-aGb-50ada-j