Whirlpool DWF 405 S Service Manual page 3

Integratable
Table of Contents

Advertisement

S E R V I C E
Technical data
Rotations
Spray pump motor
Drain pump motor
Spray arm lower
Spray arm upper
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Spray arm lower
Sprayarm upper
Ceiling rotor
Electrical base data
Voltage
Frequency
Total power
Fuse
Motor
Spray pump motor permanent spray system
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Heating
1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
(Temperature of water)
Fuse
Whirlpool Europe
Customer Service
2800
RPM
3000
RPM
30 - 40
RPM
30 - 40
RPM
208
lmp/l
45 - 65
l/min
16
l/min
1.1
m
4
l/min
~ 33
l/min
~ 27
l/min
~ 8
l/min
220/ 230 V
50
Hz
2.0 - 2.2
kW
10
A
220/ 240 V
145
W
69
48
µ F
4
220/ 240 V
30
W
146
220/ 230 V
1.87/ 2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
~ 85
˚C
206
˚C
DWF 405 S
8545 405 01770
Double electric inlet valve
Voltage
Frequency
Resistance
Regenerating valve
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reed contacts
flow meter
NTC
20 ˚C
25 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Regeneration on appliances without
potentiometer for water hardness
Volume
after wash cycles
water hardness
Salt consumption
for regeneration
Number of cycles
with 2 kg salt
Accesory
If you need spare parts apart from
the spare part list have a look
in the Service Bulletin 4812 718 40084.
23.05.2002 / Page 3
Doc. No: 4812 718 18048
220/ 240 V
50/ 60
Hz
2.0
kΩ
220/ 240 V
50/ 60
Hz
3.13
kΩ
220/ 240 V
50/ 60
Hz
1.3
kΩ
58.1
kΩ
47 .1
kΩ
38.2
kΩ
25.4
kΩ
17 .2
kΩ
11.8
kΩ
8.3
kΩ
6
kΩ
4
kΩ
3
300
cm
1
0 - 60
˚dh
0 - 10.7
mmol/l
0 - 107
˚Fh
77
g
26