Congratulations on choosing Breezair air
cooling.
Your air cooler is built from the highest
quality materials and engineered to
provide many years of economical,
trouble free cooling. It is compliant with
European safety standards.
Breezair air coolers are equally effective
in industrial, commercial and residential
buildings.
Please take a few minutes to read these
instructions so you have a full
understanding of how to operate your air
cooler. Your installer should demonstrate
the features and procedures set out in
these instructions. The installer should
also provide you with a Model and Serial
number, which can be filled out on the
last page.
If the supply cord is damaged, it must be
replaced by a special cord available from
the manufacturer or its service agents
Keep these instructions in a safe
place for future reference.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the
appliance by a person responsible for
their safety.
Children should be supervised to ensure
that they do not play with the appliance.
®
To provide efficient cooling or ventilation
the building must have sufficient natural
exhaust openings to outdoors in the form
of doors, windows or other vents. To
assist air circulation, open windows or
doors that are furthest from the outlet
vent in each room/area.
In every room/area that has an outlet
vent, provide an exhaust opening about
2 or 2.5 times the size of the outlet vent in
the room/area.
Where the design of the building prevents
adequate natural exhaust, mechanical
extraction (exhaust fan/s) may be
required.
Total minimum openings for the whole
building are demonstrated by the
following table:
Cooler Model
Please note that an average size door is
1
.5m
2

INTRODUCTION

EFFECTIVE COOLING
Total natural
exhaust area
EXH130
EXH170
EXH190
EXH210
2
2
2
2.0m
2
2.5m
2
3.0m
2
4.0m