2.3
SETT ING UP WITH A D MX512
CONT ROLLER
2.3-1 DMX512 ADDRESSING WITHOUT ID ADDR ESSING
(
STAGE 1 MOD E)
Conne ct the DMX512 controller to the units i n series .
Each u nit has 10 DMX channels so th e DMX Addr ess es should incr ease by incr ements of
10 (e.g. 1,11,21,31... )
T he ID addr es s has no t been set so th er efore when u sing the contro ller Ch9 must
be inactiv e ( CH9=0 ) .
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
Exampl e :
2.3-2 DMX512 ADDRESSING WITH ID ADDRESS STAGE 1 M ODE)
Conne ct the DMX512 controller to the units i n series
Each u nit has 10 DMX channels so th e DMX Addr ess es should incr ease by incr ements of
10 (e.g. 1,11,21,31... )
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
Each D MX addr ess may carry up to 66 separate ID a ddresses.
ID
should be s et in the menu on each unit in asce nding values
(i .e. 1,2,3...)
ID add resses ar e accessible fr om Ch 9 on the DMX512 controller.
ADD : 19 Lacist St. Wesbrark, Maine, U.S.A. (04092)
DM X512
CON TR OLL ER
7
Phonel : (1) 207-712-3004
. . . . . . . . . . . .
The figur e above sh ows a simple D MX512
layo ut with the s tart ing address of the first
uni t set at 1, with th e second set at 11 and
so o n... ( Note that when used in this way,
the CH9 ID function must be inacti v e (CH9=0))