Basic In Stru Ctions For D Mx51 2 Operation (Stage 1) - te-lighting TE-X24RGB User Manual

Minibatten
Table of Contents

Advertisement

4.3
BASIC INSTR UCTIONS FOR D MX512
OPER ATION ( STAGE 1)
MAS TER DIMMER
CH1 controls the intensity o f the currently p rojec ted color
When the sli der is at the hig hest positi on ( 255) the intensit y of the output is the maximum
RED , GRE EN & BL U E COLOR SE LE CTIO N
CH2, CH3 & CH4 control the intensity ratio of each of the RED, GREEN & BLUE LEDs.
When the sli der is at the hig hest positi on ( 255) the intensit y of the color is the maximum.
CH2, CH3 & CH4 can be com bined togethe r to create over 16 mil lion colo rs .
COL OR MACROS
CH5 selects the required CO LO R MACRO
CH5 has pr ior ity over CH2, C H3 and CH4
CH1 is used to control the in tensity of the CO LO R MACRO
STROBE
CH 6 control s the str obe of C H1 to CH5
ID ADDRE SS S EL EC TION
CH9 is used to selec t the tar get ID addr ess .
Each indepe ndent DMX add ress may have upto 66 independent ID addr esses.
An ID addres s of 0 will activa te all ID addre ss loc ations .
AUT O
CH7 selects the F an F unctio n, the preset A UTO pr ograms Auto 01-10 or t he custom prog rams
Custom 01-1 0
CH7 has pr ior ity over CH2, 3 , 4, 5.
CH8 control s peed of CH 7.
BLOCK
T his fixture i s divided as 4 b locks, each bloc k include 2 red Leds, 2 gr een leds, 2 blue leds.