Oliver IGD TOCSIN 102 SERIES Operation Manual

Toxic or oxygen gas detector pellistor
Hide thumbs Also See for TOCSIN 102 SERIES:

Advertisement

Quick Links

TOCSIN 102, 103
TOC-30 SERIES
OPERATION MANUAL
REFERS TO MODELS 5131401ATEX, 5137001, TOC-30A-PHC and TOC-31A-PHC
&
PELLISTOR
Ref T102P-VERSION 6.00
O L I V E R
Oliver IGD Limited
Triton House
Crosby St
SK2 6TS
England
Tel:
+44(0)161 483 1415
Fax:
+44(0)161 484 2345
Email:
Sales@internationalgasdetectors.com
Web Site:
www.internationalgasdetectors.com
I G D

Advertisement

loading

Summary of Contents for Oliver IGD TOCSIN 102 SERIES

  • Page 1 TOCSIN 102, 103 & TOC-30 SERIES PELLISTOR OPERATION MANUAL REFERS TO MODELS 5131401ATEX, 5137001, TOC-30A-PHC and TOC-31A-PHC O L I V E R I G D Oliver IGD Limited Triton House Crosby St SK2 6TS England Tel: +44(0)161 483 1415 Fax:...
  • Page 2 This instruction manual is intended fo ruse by competent persons who can either demonstrate previous experience and training with gas detection systems or have completed training courses at Oliver IGD Limited. Performance of the system will be a function of how well the system is installed and calibrated.
  • Page 3 OLIVER CUSTOMER SEALING AND EARTHING RESPONSABILITIES The Tocsin 102 Pellistor model 5131401ATEX is designed for use in Zone 1 and Zone 2 hazardous areas and is ATEX certified. To maintain compliance it is imperative the installer of the equipment observes the following installation guidelines.
  • Page 4 OLIVER Non ATEX versions with MK6 detectors, Mounting Details The non-ATEX version, 103 series flammable gas detector is typically fitted in areas that do not require a flameproof gas detector approval. Typical applications would be boiler rooms, school laboratories, commercial kitchens etc. Cabling should have a suitable level of protection for the area into which the detector is fitted and be of a screened type such as CY style cable or FP200 style cable.
  • Page 5 P Y W PC Terminal A D D R E S S A B L E O U T P U T Connector The Oliver IGD universal pellistor CHASS Interface Terminals drive PCB is designed to take input T106P V2...
  • Page 6 OLIVER TOCSIN 106P U N I V E R S A L P E L L I S T O R Initial Power Up D R I V E P C B A N A L O G U E O R A D D R E S S A B L E O U T P U T With power applied the FAULT LED will flash...
  • Page 7 OLIVER OPTION 1 4-20mA SYSTEMS Setting Zero TOCSIN 106P Press and hold the UP button U N I V E R S A L P E L L I S T O R until the ZERO LED is D R I V E P C B CHASS illuminated.
  • Page 8 OLIVER TOCSIN 106P These two options relate to early versions pre 2015 U N I V E R S A L P E L L I S T O R D R I V E P C B A N A L O G U E O R OPTION 3 I ZERO (INSTANTANEOUS ZERO) A D D R E S S A B L E O U T P U T Setting Instantaneous Zero...
  • Page 9 OLIVER TOCSIN 106P Setting The Unit Address U N I V E R S A L P E L L I S T O R D R I V E P C B CHASS A N A L O G U E O R T106P V2 +24V A D D R E S S A B L E O U T P U T...