Gas fired storage water-heater for sanitary hot water production with atmospheric burner (18 pages)
Summary of Contents for Strebel SP 150
Page 1
0694 SP 220 SP 150 SP 300 SP 600 SP 170 SP 400 SP 800 Gas fired storage water heaters with sealed combustion chamber (C type) and forced flue draft MANUAL OF INSTALLATION GENERAL INFORMATION AND CHARACTERISTICS INSTRUCTIONS TO THE INSTALLER...
Page 2
WARNING • • • • The following instruction book is an integral and essential part of the appliance and it has to be kept with care near the appliance, for any further consultation. • • • • The appliance has been conceived for hot water production: any other use of it has to be considered dangerous and not suitable.
INDEX ................ page 1.1 TECHNICAL DATA 1.2 APPLIANCE CLASSIFICATION 1.3 PACKAGING CONTENT 1.4 OPERATIONAL AND FUNCTIONAL DESCRIPTION 1.5 CONTROL AND SAFETY DEVICES 1.6 DIMENSIONS AND CONNECTIONS 2.1 REFERENCE REGULATIONS 2.2 RECOMANDATIONS FOR THE INSTALLATION 2.3 FLUE HOOD INSTALLATION 2.4 WATER CONNECTIONS 2.5 GAS CONNECTIONS 2.6 GAS SUPPLY SETTING 2.7 GAS SUPPLY CONVERSION...
1 – GENERAL INFORMATION AND CHARACTERISTICS CATEGORY OPERATIONAL AND FUNCTIONAL The countries of destination and the categories are listed DESCRIPTION in the chart here below. The purpose of the appliance is to allow the heat exchange between the gas combustion products, burned inside the Country Category Country Category combustion chamber, and the water stored in the tank.
1 – GENERAL INFORMATION AND CHARACTERISTICS FLUE SYSTEMS Electrical supply 220/240 V - 50 Hz (Installing original kits supplied Power consumption 15 W manufacturer of the appliance is compulsory) Electrical protection degree IP 54 The flue system has to be chosen according to the installation requirements.
Page 7
1 – GENERAL INFORMATION AND CHARACTERISTICS HIGH TEMPERATURE LIMIT THERMOSTAT Technical features This thermostat will turn the burner off in case of a too Contacts rating (C-1) 250 V~ / 0,5 A high water temperature caused by a bad operation of the Contacts rating (C-2) 250 V~ / 15(2,5) A adjustable thermostat.
1 – GENERAL INFORMATION AND CHARACTERISTICS DIMENSIONS AND CONNECTIONS MODELS 150 - 170 fig_1-06-01 (measures in mm) mod. OVERALL HEIGHT 1.905 2.105 HEIGHT FLUE 1.790 1.990 SYSTEM HOT WATER OUTLET C - 1"1/4 1.625 1.825 RETURN CONNECTION R - 1" GAS CONNECTION G - 1/2"...
Page 9
1 – GENERAL INFORMATION AND CHARACTERISTICS MODELS 220-300-400-600-800 fig_1-06-02 (measures in mm) mod. OVERALL HEIGHT 1.560 1.912 2.275 1.950 2.310 HEIGHT OF THE 1.445 1.795 2.145 1.830 2.195 FLUE SYSTEM WATER C - 1"1/4 1.285 1.640 1.985 1.655 2.030 OUTLET RETURN R - 1"...
2 – INSTRUCTIONS TO THE INSTALLER REFERENCE REGULATIONS fan assembly C. Ø 60/100 coaxial fitting with flue sampling plastic bag with fixing screws ACCORDING TO THE REGULATIONS OF THE COUNTRY WHERE THE HEATERS WILL BE INSTALLED RECOMANDATIONS FOR THE INSTALLATION The installation must be performed by a qualified installer, in accordance with the regulations in force.
2 – INSTRUCTIONS TO THE INSTALLER mod. 150-170 fig_2-03-08 fig_2-03-09 Connect the coaxial fitting. fig_2-04-01 A (cold water inlet) Install in the following order: 1. a non-return valve (suggested) 2. a softener or a purifier, where conditions of high or extreme water hardness exist (recommended for fig_2-03-10 values over 50°F)
2 – INSTRUCTIONS TO THE INSTALLER The return circuit is compulsory for mod. 300-400-600- The gas supply conversion must be carried out by a 800. qualified technician. D (drain) Connect a drain cock. mod. 150-170 E (pressure relief valve connection) Connect the ½”...
2 – INSTRUCTIONS TO THE INSTALLER Undo the nozzles B and replace them with the ones contained in the kit. Fully tighten in order to ensure gas soundness Only for mod. 220-300-400-600-800: remove the air regulator C from the burner collector. Set the pressure at the injector by adjusting the screw D till the value for gas supply with natural gas is reached (see table at point 2.6).
2 – INSTRUCTIONS TO THE INSTALLER 2.10 FLUE SYSTEMS HORIZONTAL COAXIAL KIT Proper extension pipes are available to increase the Ref. AKIT01 (configuration C12) length of the kit (see below). The maximum length is 3 m. It is possible to add till two 90° elbows (in this case, each elbow added makes the length of the kit 1 m shorter).
Page 15
2 – INSTRUCTIONS TO THE INSTALLER HORIZONTAL SINGLE WALL FLUE SYSTEM Proper extension pipes are available to increase the Ref. AKIT02 (configuration C12 – C52 – C82) length of the kit (see below). The maximum length is 6 m for both air and flue duct (if you reduce the length of the air duct you cannot increase the length of the flue one and vice versa).
2 – INSTRUCTIONS TO THE INSTALLER 2.11 WIRING fig. 2_11 GROUPS COMPONENTS COLOUR OF flame detection ignition electrode CABLES printed circuit flame detection electrode white instrument control panel line trap bl: blue fuse for printed circuit (2A) grey On/Off switch m: brown differential pressure switch black...
2 – INSTRUCTIONS TO THE INSTALLER 2.12 STARTING THE APPLIANCE appliance goes into lock-out during normal functioning. Before starting the water-heater ensure that: the gas supply has been interrupted, even temporarily: The gas supplied is the one for which the appliance is the control box has not detected the presence of flame and it has gone to lock-out Current...
3 –INSTRUCTIONS TO THE USER RECOMMENDATIONS FOR THE USER re-set the control box by pushing the reset button. The lock-out light will turn off. This booklet is an integral and essential part of the appliance and it 4. After the burner ignition, which is signalled by the has to be kept with care near the appliance, for any further lightening of the green light “E”, the water heating consultation.
3 –INSTRUCTIONS TO THE USER FREQUENTLY ASKED QUESTIONS Can we use a water-softener? The use of a water-softener reduces the protective effect magnesium anode and, consequence, the working life of the tank. The manufacturer suggests not softening the water to a water hardness lower than 15 °F.
Page 20
Water-heater model SP 150 SP 170 SP 220 SP 300 SP 400 SP 600 SP 800 is in conformity with the European Directive Gas appliances Directive 2009/142/CE – Low Voltage Directive 2006/95/CE – Electromagnetic Compatibility Directive 2004/108/CE – 210-0388 - October 2012...
Need help?
Do you have a question about the SP 150 and is the answer not in the manual?
Questions and answers