#2: Supported loads

As a dimmer it operates under the following loads:
120V operated conventional incandescent and halogen light
sources
12V operated ELV halogen lamps and dimmable LED bulbs (with
electronic transformers)
12V operated MLV halogen lamps (with ferromagnetic
transformers)
dimmable LED bulbs
dimmable compact fluorescent CFL tube lamps
supported dimmable light sources (power factor > 0.5) with
minimal power of 5VA using FIBARO Bypass 2 (depending on the
type of load)
Without dimming function it may work with:
compact fluorescent CFL tube lamps with electronic ballast
fluorescent tube lamps with electronic ballast
LED bulbs (power factor > 0.7)
supported light sources (power factor > 0.5) with minimal power
of 5VA using FIBARO Bypass 2 (depending on the type of load)
Applied load and the Dimmer 2 itself may be damaged if
!
the applied load is inconsistent with the technical specifi-
cations!
When connecting FIBARO Dimmer 2 act in accordance with the
following rules:
Do not connect loads greater or less than those recommended
Do not connect different types of light sources simultaneously
Do not connect the power supply without a load
Do not connect more than one transformer with Dimmer 2 output
When using magnetic transformer load it with 50% of its nominal
power at minimum
Minimize number of electronic transformers in a circuit, noises
caused by them in electrical grids may affect Dimmer's operation
5
!
CAUTION
FIBARO
Dimmer
2
supports only com-
pact fluorescent tube
lamps and fluorescent
tube lamps with elec-
tronic ballast. Do not
connect other types
of fluorescent lamps!