#12: Additional functionality
Software update
Dimmer 2 features remote software update (initiated by the main
controller). Update status is signalled by the LED indicator with cyan
colour:
•
slow blinking - transferring data via Z-Wave and saving to the
flash memory
•
fast blinking - copying data from the external memory to the
memory of the microcontroller
Operating alarm data frames
FIBARO System allows user to set response of devices to alarm situa-
tions (response to data-frames ALARM_REPORT and SEnSOR_ALARM_
REPORT). Dimmer 2 responds to the following types of alarms:
•
General Purpose Alarm - GEnERAL PURPOSE ALARM
•
Smoke Alarm - ALARM CO2, ALARM CO, ALARM SMOKE
•
Water Flooding Alarm - ALARM WATER
•
Temperature Alarm - ALARM HEAT
Alarm data-frames are sent by devices that are system sensors (e.g.,
flood sensors, smoke detectors, motion detectors, etc.).
The device may respond in the following manner to received da-
ta-frames (settings are configured in configuration parameters, see
„Advanced parameters" on page 22):
0 - DEACTIVATION - the device does not respond to alarm data frames
1 - DIMMER 2 ON - the device turns on after detecting an alarm
2 - DIMMER 2 OFF - the device turns off after detecting an alarm
3 - ALARM FLASHING - the device periodically changes its status to
the opposite when it detects an alarm (lights on/off alternately)
ADDITIOnAL FUnCTIOnALITY