York P*UR Installation Instructions Manual page 6

High efficiency gas-fired furnaces tubular heat exchanger series
Hide thumbs Also See for P*UR:
Table of Contents

Advertisement

B
A
FRONT
B
VENT CONNECTION
(VENT SIZE
20
POWER
WIRING
7/8 K.O.
5-3/8
1-7/8
E
F
FRONT
TOP IMAGE
RETURN END
DIMENSIONS - DOWNFLOW/HORIZONTAL MODELS: P*DH/G9T-DH/FG9-DH
FIGURE 2 :
Table 2: RATINGS & PHYSICAL / ELECTRICAL DATA - DOWNFLOW/HORIZONTAL MODELS
MODELS P*DH/
FG9-DH/G9T—DH
INPUT
OUTPUT
NOM.
MBH
MBH
CFM
40
37
1000
60
55
1200
80
75
1200
80
75
1600
100
95
2000
120
112
2000
*.
AFUE numbers are determined in accordance with DOE test procedures
†.
Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition).
For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. Refer to instruction 035-14460-000.
Wire size based on copper conductors, 60°C, 3% voltage drop.
Continuous return air temperature must not be below 55°F.
6
20
3/4
T'STAT WIRING
7/8 K.O.
CONDENSATE
DRAIN ACCESS
3-1/4 x 3
5-1/4
AIR INTAKE
45
3-5/8 x 3-5/8
1-1/4
G
(
CONN. SIZE/
PIPE SIZE)
GAS INLET
1-1/4 x 2-1/2
28-1/2
LEFT SIDE
A
19-1/4
C
H
FRONT
BOTTOM IMAGE
RETURN END
AIR
CABINET
*
TEMP
AFUE
WIDTH
RISE °F
14-1/2
91.0
25 - 55
17-1/2
91.0
35 - 65
17-1/2
91.0
35 - 65
21
91.0
30 - 60
21
91.0
40 - 70
24-1/2
91.0
40 - 70
D
VENT CONNECTION
1-3/4
35
16-3/4
18-1/2
3-3/4
7-1/2
6-1/4
2-3/4
MODELS P*DH /
1-3/8
G9T-DH / FG9-DH
40/37/1000/A
60/55/1200/B
80/75/1200/B
80/75/1600/C
8
100/95/2000/C
120/112/2000/D
1. VENT PIPE MUST BE INCREASED TO 3" ON THIS MODEL.
ALL DIMENSION ARE IN INCHES, AND ARE APPROXIMATE.
BLOWER
MAX.
OUTLET
AIR
HP AMPS SIZE (IN)
TEMP. °F
155
1/3
6.2
165
1/2
7.0
165
1/2
7.0
160
3/4
11.5
170
1
12.2
170
1
12.2
035-17477-001 Rev. A (801)
CONDENSATE
DRAIN ACCESS
3-1/4 x 3
3-3/4
AIR INTAKE
3-5/8 x 3-5/8
G
(
CONN. SIZE/
PIPE SIZE)
1-1/4
ALT. GAS INLET
4-1/8
1-1/4 x 2-1/2
RIGHT SIDE
A
B
C
D
14-1/2
13-1/4
11-3/4
2
17-1/2
16-1/4
14-3/4
2
17-1/2
16-1/4
14-3/4
2
21
19-3/4
18-1/4
2
21
19-3/4
18-1/4
2
1
24-1/2
23-1/4
21-3/4
2 (3)
MAX
TOTAL
OVER-
UNIT
CURRENT
AMPS
PROTECT
10 x 6
9.0
20
11 x 8
12.0
20
11 x 8
12.0
20
11 x 8
12.0
20
11 x 10
14.0
20
11 x 10
14.0
20
Unitary Products Group
E
F
G
5-1/8
2-1/2
2
6-5/8
2-1/4
2
6-5/8
2-1/4
2
8-3/8
2-1/4
2
8-3/8
2-1/4
2
10-1/8
2-1/4
3
MIN WIRE
SIZE
(AWG) @
75 FT. ONE
WAY
14
14
14
14
12
12