Type Numbers; Power Supply; Recommended Battery Types; Replacing The Batteries - Philips LBB 6030 Installation Instructions Manual

Ps-micro mobile alarm transmitters
Table of Contents

Advertisement

INSTALLATION INSTRUCTION 94
May 1999. Page 3
1.1

Type Numbers

This Installation Instruction covers the following type numbers:
LBB 6030/xx
Mobile with Manual alarm
LBB 6031/xx
Mobile with Manual alarm and location detection
LBB 6032/xx
Mobile with Manual, Not-vertical and No-move alarm
LBB 6033/xx
Mobile with Manual, Not-vertical, No-move alarm and location detection
LBB 6034/xx
Mobile with Manual, Not-vertical, No-move and Tear-out alarm
LBB 6035/xx
Mobile with Manual, Not-vertical, No-move, Tear-out alarm + location detection
/xx indicates the operational frequency of the mobile.
2.
P
OWER SUPPLY
The power to the mobiles is supplied by two LRI sized rechargeable or non-rechargeable batteries (fig. 1 K) or by a
single 3 V (non-rechargeable) lithium type Sanyo CR12600 SE battery. The choice between rechargeable and non-
rechargeable batteries is made by a 3-position switch located inside the mobiles battery compartment (fig. 1L). See
also section 2.2.
WARNING: Never charge non-rechargeable batteries. Always place the programming switch in the mid-
dle position (2) (fig. 1L) for these kind of batteries.
2.1

Recommended battery types

Rechargeable: LBB 5931/02 or batteries with identical specification
Non-rechargeable batteries: Philips Alkaline type LR1 LBB 5312/00 or identical specification
NOTE: When placed in a Philips storage or charging rack type LBB 6150/00, /01, /02 and LBB 6152/00
the mobile receives its power from the charging/storage rack and not from the batteries, however batter-
ies are needed for full operation in a rack.
2.2

Replacing the batteries

1. Opening the battery cover
To open the battery cover, slide the battery cover lock (fig.1 F) in the direction of the clip.
Use the special tool delivered with the mobile to unscrew the locking screw (fig. 1M) located underneath the
battery cover.
Slide the battery cover (fig.1G) downwards
Remove the battery(s)
2. Battery type selection
Remove the battery(s) (fig.1K)
Locate the 3-position slide switch at the rear of the battery housing (fig. 1L).
Upper Position 1 = Programming/diagnostics mode only
Middle Position 2 = Non rechargeable disposable batteries
Lower Position 3 = Rechargeable batteries
3. Battery replacement
Place the new battery(s) in the correct position (fig.1K) If rechargeable batteries are used ensure the batteries
are charged before using the mobile.
Close and lock the battery cover.
NOTE: Never leave dead batteries in the mobile and never leave batteries in the mobile during transpor-
tation.
Sanyo type CR12600 SE (1 per mobile)