Value Of Thermistor - Haier HSU-18LEK03/R2 Service Manual

Wall mounted type dc inverter ek-series
Table of Contents

Advertisement

5.2.5.5 The frequency limitation of modification rate
In the field which is controlled by high frequency, if the modification rate is not high enough, the
control-driven chip will enter into weak magnetic control, this will help to relieve the problem of
modification rate. If during the course of weak magnetic control, the modification rate is still not high
enough, enter into the control of decreasing frequency until the alarm of modification rate is relieved.
5.2.5.6 Temperature protection of the outdoor refrigerating coil
When the defrosting temperature and the sensor's temperature are higher than 65 , the frequency of
the compressor decreases 1hz/10seconds. Keep the frequency until it decreases to the lowest
frequency. When the temperatures are lower than 65
the compressor. When the temperatures are lower than 60 , relieve the defrosting temperature
protection.

5.3 Value of Thermistor

5.3.1 intdoor Unit
R25 =10K
3%
B25 /50 =3700K 3%
Temp.(( ))
-30
-29
-28
-27
-26
-25
-24
-23
-22
-21
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
Room sensor and Pipe Sensor
Max.(KΩ)
Normal(KΩ)
165.2170
147.9497
155.5754
139.5600
146.5609
131.7022
138.1285
124.3392
130.2371
117.4366
122.8484
110.9627
115.9272
104.8882
109.4410
99.1858
103.3598
93.8305
97.6556
88.7989
92.3028
84.0695
87.2775
79.6222
82.5577
75.4384
78.1230
71.5010
73.9543
67.7939
70.0342
64.3023
66.3463
61.0123
62.8755
57.9110
59.6076
54.9866
56.5296
52.2278
53.6294
49.6244
and higher than 60 , keep the frequency of
Min.(KΩ)
132.3678
125.0806
118.2434
111.8256
105.7989
100.1367
94.8149
89.8106
85.1031
80.6728
76.5017
72.5729
68.8710
65.3815
62.0907
58.9863
56.0565
53.2905
50.6781
48.2099
45.8771
25
Functions and Control
Tolerance( )
-1.94
1.75
-1.93
1.74
-1.91
1.73
-1.89
1.71
-1.87
1.70
-1.85
1.69
-1.83
1.67
-1.81
1.66
-1.80
1.64
-1.78
1.63
-1.76
1.62
-1.74
1.60
-1.72
1.59
-1.70
1.57
-1.68
1.55
-1.66
1.54
-1.64
1.52
-1.62
1.51
-1.60
1.49
-1.58
1.47
-1.56
1.46
Domestic Air Conditioner